8
Figure 7
IF THE X-62 IS TO BE OPERATED ON NATURAL GAS, PROCEED TO STEP #8.
7. The X-62 can operate on either Natural Gas or L.P. Gas. It arrives from the factory set up for operation on
Natural Gas. If the appliance is to be operated on L.P. Gas, a qualified technician must convert the gas valve
and the pilot from Natural Gas to L.P. Gas, and install all of the components in the L.P. Conversion Kit that is
provided with the appliance. To convert the appliance to L.P. Gas (see Fig.5):
a. Take out the burner: Remove the 4 screws that hold the burner to the firebox floor (see Fig.5, page 4).
Slide the burner to the left to disengage its inlet tube from the shutter box. Lift the burner up.
b. Take out the firebox floor by removing the 6 screws that hold it to the firebox (see Fig 5, page 4).
c. Unscrew and remove the Natural Gas orifice that was shipped with the X-62 (see Fig.4, page 4). Save
the orifice removed from the appliance for future use. [
Conservez les injecteurs retirés de ĺappareil
pour utilisation future.]
d. Screw the L.P. orifice (which is part of the L.P. Conversion Kit) over the fitting on the gas valve.
e. To convert the valve to L.P. Gas, remove the rubber cap that covers the valve conversion stem.
Depress the stem and rotate it clockwise until it locks in place in the depressed position. Replace the
rubber cap. (See Fig.4, page 4.)
f.
To convert the pilot to L.P. Gas, loosen the ½‖ hex fitting under the pilot hood, slide the quick adjust
lever forward (the lever is just below the hex fitting), and tighten the hex fitting (see Fig. 8).
g. Reinstall the firebox floor, the front vent plate, and the burner, in that order. To reinstall the burner, set
it in place in the left side of the opening in the firebox floor (the opening of the burner inlet tube should
be pointing to the right. Slide the burner to the left until the inlet tube engages with the shutter box
and the screw holes line up. Screw the burner in place.
Figure 8
To convert the X-62 back to natural gas, replace the L.P. orifice with the Natural Gas orifice according to the
instructions above. Also convert the gas valve and the pilot back to natural gas. Remove the rubber cap that
covers the valve conversion stem. Push in on the stem and rotate it counterclockwise until it pops out to its
full extension. Replace the rubber cap. To convert the pilot, loosen the ½‖ hex fitting under the pilot hood,
slide the quick adjust lever backward (the lever is just below the hex fitting), and tighten the hex fitting.