background image

 

 

Figure 7 

 

IF THE X-62 IS TO BE OPERATED ON NATURAL GAS, PROCEED TO STEP #8. 

 

7.  The X-62 can operate on either Natural Gas or L.P. Gas.  It arrives from the factory set up for operation on 

Natural Gas.  If the appliance is to be operated on L.P. Gas, a qualified technician must convert the gas valve 
and the pilot from Natural Gas to L.P. Gas, and install all of the components in the L.P. Conversion Kit that is 
provided with the appliance.  To convert the appliance to L.P. Gas (see Fig.5): 

 

a. Take out the burner:  Remove the 4 screws that hold the burner to the firebox floor (see Fig.5, page 4).  

Slide the burner to the left to disengage its inlet tube from the shutter box.  Lift the burner up. 

b. Take out the firebox floor by removing the 6 screws that hold it to the firebox (see Fig 5, page 4). 
c.  Unscrew and remove the Natural Gas orifice that was shipped with the X-62 (see Fig.4, page 4).  Save 

the orifice removed from the appliance for future use. [

Conservez les injecteurs retirés de ĺappareil 

pour utilisation future.] 

d. Screw the L.P. orifice (which is part of the L.P. Conversion Kit) over the fitting on the gas valve. 
e. To convert the valve to L.P. Gas, remove the rubber cap that covers the valve conversion stem.  

Depress the stem and rotate it clockwise until it locks in place in the depressed position.  Replace the 
rubber cap.  (See Fig.4, page 4.) 

f. 

To convert the pilot to L.P. Gas, loosen the ½‖ hex fitting under the pilot hood, slide the quick adjust 

lever forward (the lever is just below the hex fitting), and tighten the hex fitting (see Fig. 8). 

g. Reinstall the firebox floor, the front vent plate, and the burner, in that order.  To reinstall the burner, set 

it in place in the left side of the opening in the firebox floor (the opening of the burner inlet tube should 
be pointing to the right.  Slide the burner to the left until the inlet tube engages with the shutter box 
and the screw holes line up.  Screw the burner in place. 
 

 

Figure 8 

 

To convert the X-62 back to natural gas, replace the L.P. orifice with the Natural Gas orifice according to the 
instructions above.  Also convert the gas valve and the pilot back to natural gas.  Remove the rubber cap that 
covers the valve conversion stem.  Push in on the stem and rotate it counterclockwise until it pops out to its 
full extension.  Replace the rubber cap.  To convert the pilot, loosen the ½‖ hex fitting under the pilot hood, 
slide the quick adjust lever backward (the lever is just below the hex fitting), and tighten the hex fitting. 

 

Содержание X-62

Страница 1: ...il QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez aucun interrupteur Ne pas vous servir des t l phones se trouvant dans le b timent o vous vous trouvez Appelez...

Страница 2: ...S 7 W C 6 5 W C MIN 10 5 W C MAX L P GAS 11 W C 12 2 W C MIN 13 W C MAX GAS INLET 3 8 N P T INTERTEK TESTED TO AGA ANSI STANDARD Z21 60 2003 CAN CGA 2 26 M03 CGA CR93 0004 This appliance may be used w...

Страница 3: ...outside in accordance with the latest edition of the Natural Fuel Gas Code Do not connect this appliance to a chimney flue serving a separate solid fuel burning appliance The X 62 is a decorative gas...

Страница 4: ...E 4 V A LV E P R E S S U R E T A P F IT T IN G F O R T E S T IN G M A N IF O LD P R E S S U R E B LO W E R A D JU S T M E N T D A M P E R O P E N N A T L P C O N V E R S IO N S T E M R E D R E D B LA...

Страница 5: ...uld not be installed in any fireplace that is normally subject to severe downdrafts Downdraft conditions exist if when starting a wood fire it is difficult to establish a good upward draw i e smoke an...

Страница 6: ...ies and codes NEVER use plastic pipe GAS PRESSURE REQUIREMENTS A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLIANCES IS IMPROPER GAS PRESSURE Such problems as changes in flame color or configuration...

Страница 7: ...uired by local codes or if the supply gas pressures exceed PSIG 3 5KPA and a regulator of sufficient capacity b Flex hose used to connect the appliance must have brass to brass fittings c The gas pres...

Страница 8: ...to L P Gas remove the rubber cap that covers the valve conversion stem Depress the stem and rotate it clockwise until it locks in place in the depressed position Replace the rubber cap See Fig 4 page...

Страница 9: ...ls Spread the coals on top of the burner to produce a glowing ember effect and also around the base of the burner to conceal it see Fig 6 DO NOT spread any coals over the slots at the front of the app...

Страница 10: ...f the flame improves Tighten the nut of the air shutter Replace the front vent plate and screw it to the firebox floor NOTE If sooting persists turn off the appliance and call your Mendota dealer 19 I...

Страница 11: ...of the grate bar as shown Make sure that the log is tight against the back of the firebox Place the notch on log 2 over the left grate bar Slide log 2 back against the tabs that are located on the to...

Страница 12: ...osition pinned log 6 so that its left end is in contact with the right end of log 2 Log 3 rests on log 2 with its right end against the grate bar as shown in the circled area Log 5 rests in the notche...

Страница 13: ...nuously until it is turned off Press the HI button on the remote to operate the appliance with maximum flame and heat Press the LOW button on the remote to operate the appliance with minimum flame and...

Страница 14: ...The gas supply is turned off C The batteries in the remote and or receiver need replacing D The remote needs to be synchronized with the receiver E The pilot assembly is dirty F Any other cause A Mak...

Страница 15: ...valve and the air shutter on the venturi Use a brush or wire to clean the inlet of the venturi Clean foreign matter and carbon deposits from the burner pan and burner tiles Check to see that the burne...

Страница 16: ...COALS HA 74 00028 VALVE ASSEMBLY 05 02 00331 VALVE 05 02 00330 VALVE SOLENOID HA 74 00003 BURNER ASSEMBLY 05 04 00045 PILOT ASSEMBLY 65 14 00025 NATURAL GAS ORIFICE 25 65 14 00043 L P GAS ORIFICE 43...

Страница 17: ...the back of the firebox and the brick pattern must face forward NOTE The rear brick panel is held in place by the left and right brick panels DO NOT let the rear panel fall forward before the side pan...

Страница 18: ...18 NOTES...

Страница 19: ..._____________________________ DATE INSTALLED __________________________________ REF X 62 INSTALLATION MANUAL THE EXISTING FIREPLACE CHIMNEY MEET ALL OF THE REQUIREMENTS see page 5 THE GAS SUPPLY MEETS...

Страница 20: ...20...

Страница 21: ...nty does not cover glass or log breakage Cracks in the burner ceramic plaques is normal and not covered under warranty unless pieces of the ceramic are missing Mendota has the right to investigate and...

Страница 22: ...22 Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 Mendota Hearth Division 85 03 00738 C...

Отзывы: