INSTALLATION INSTRUCTIONS
NOTE
: The X-62 Gas Log Insert must be installed only by a qualified technician.
1. Check to be sure that the fireplace into which the X-62 is to be installed meets
ALL
of the installation
requirements listed on page 5, that is:
a. The fireplace
must
be vented and non-combustible, have a working flue, and be approved for burning
solid fuel. It
must not
be located in a bathroom, or in any room where sleeping accommodations are
provided.
b. The fireplace
must
be at least 30 ½‖ wide by 24‖ high by 16 ½‖ deep.
c. The chimney opening of the fireplace
must
equal or exceed the minimum opening for the height of the
chimney, as listed in the CHIMNEY OPENING chart on page 5.
d. The fireplace
must not
be subject to severe downdrafts during the normal course of its operation.
e. The chimney flue
must not
serve a second solid-fuel-burning appliance.
f. The chimney of the fireplace
must
be equipped with a chimney cap.
2. Check to see that the gas supply meets ALL of the requirements listed on page 6, that is:
a. The gas supply line
must
of the proper material and
must
be of the proper diameter, as listed in the
GAS SUPPLY LINE SIZING chart on page 6. Also, the gas supply line
must
have a drip leg, a shut-
off valve (if one is required by local codes
or
if the supply gas pressures exceed ½ PSIG [3.5KPA]),
and a regulator of sufficient capacity.
b. Flex hose used to connect the appliance
must
have brass-to-brass fittings.
c. The gas pressure
must
meet the requirements listed in the INLET GAS PRESSURE chart on page 6.
3. Remove any glass doors, grates, combustible materials, etc. from the existing fireplace.
4. Have the fireplace and venting system cleaned by a certified chimney sweep or qualified service technician.
The damper of the fireplace must be modified to maintain at least the minimum opening required for
the height of the chimney, as listed in the CHIMNEY OPENING chart on page 5. It is recommended
either to remove the damper completely, or to cut a hole in the damper equal the minimum opening
required. A large damper may be permanently fixed open with a screw or bolt in its edge, provided that
the opening meets the minimum requirements.
NOTE:
Massachusetts requires that the existing fireplace flue damper must be removed or
permanently welded in the "open" position.
5. Remove the log package, the bag of coals, the grate, the bag containing the remote and batteries, the L.P.
conversion kit, the packing material, and any other loose items in the firebox. Set the X-62 in front of the
fireplace.
6. Take out the front vent plate by removing the 2 screws that hold it to the firebox floor (see Fig. 6). Plug the
receiver wire into the receiver (see Fig. 7, page 8).