Children and adults should be 

ALERTED

 to the hazards of high surface temperature and should 

STAY AWAY

 to avoid 

burns or clothing ignition. 
Les enfants et les adultes devraient être informés des dangers que posent les températures de surface élevées et se tenir 
à distance afin d’éviter des brûlures ou que leurs vêtements ne s’enflamment. 
 
Young children should be 

CAREFULLY SUPERVISED

 when they are in the same room as the appliance. 

Toddlers, young 

children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in 
the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk 
individuals out of the room and away from hot surfaces.   
“Les jeunes enfants devraient être surveillés étroitement lorsqu’ils se trouvent dans la même pièce que l’appareil. Les tout petits, les  
jeunes enfants ou les adultes peuvent subir des brûlures s’ils viennent en contact avec la surface chaude. Il est recommandé d’installer 
une barrière physique si des personnes à risques habitent la maison. Pour empêcher l’accès à un foyer ou à un poêle, installez une 
barrière de sécurité; cette mesure empêchera les tout petits, les jeunes enfants et toute autre personne à risque d’avoir accès à la 
pièce et aux surfaces chaudes.

 

 
These units 

MUST

 use one of the vent systems described in the Flue Venting section of this manual. 

This gas fireplace and vent assembly 

MUST

 be vented directly to the outside and 

MUST NEVER

 be attached to a chim-

ney serving a separate solid fuel-burning appliance. Each gas appliance 

MUST USE

 a separate vent system. Common 

vent systems are 

PROHIBITED

 
The vent system assembly for this fireplace must be periodically examined by a qualified service agency. 
 
If the vent-air intake system is disassembled for any reason, reinstall per the instructions provided for the initial installa-
tion. 
 

INSPECT

 the external vent cap on regular basis to make sure that no debris is interfering with the airflow.  The flow of 

combustion and ventilation air not to be obstructed 
 

DO NOT

 abuse the glass door by striking the glass, slamming the door shut, etc. 

Use only authorized parts and materials obtained from Johnson Gas Appliance Company when replacing defective or 
damaged glass.  
 

DO NOT USE

 abrasive cleaners on the glass door assembly. 

DO NOT ATTEMPT

 to clean the glass door when it is hot. 

 
Turn off the gas before servicing this appliance. It is recommended that a qualified service technician perform an appli-
ance check-up at the beginning of each heating season. 
 

DO NOT place furniture or any other combustible household objects within 36 inches of the fireplace front.

 

This vented gas fireplace heater is not for use with air filters”.  
Foyer au gaz à évacuation.- Ne pas utiliser avec du combustible solide.

 

Keep burner and control compartment clean.  See installation and operating instructions accompanying appliance."  
S'assurer que le brûleur et le compartiment des commandes sont propres.  Voir les instructions d'installation et 
d'utilisation qui accompagnent l'appareil.

 

 
WARNING:

  Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.  

Refer to the owner’s information manual provided with this appliance.  For assistance or additional information consult a 
qualified installer, service agency or the gas supplier. 

L'AVERTISSEMENT:

  L'installation inconvenante, ajustement, modification, service ou entretien peut causer le 

dommages de propriété ou blessure.  Référer au manuel d'information de propriétaire fourni cet appareil.  Pour 
l'assistance ou information supplémentaire consulte un qualifiée installeur, agence de service ou le fournisseur de gaz.

 

 

DO NOT USE 

this appliance if any part has been under water. Immediately 

CALL

 a qualified service technician to inspect 

the appliance and to replace any part of the control system and any gas control, which has been underwater.

 

 

This appliance is for use with only doors certified by Mendota. Do not use any fronts or doors with this appliance unless 
they are certified by Mendota and installed by a certified installer.

Содержание FV34-ARCH-PF2

Страница 1: ...nt Installation and service must be performed by a qualified installer service agency or the gas suppli er WARNING Do NOT use this appliance if any part has been under water Immediately call a qualifi...

Страница 2: ...yd based Paints PROPER SEALANTS TYPE APPROVED FOR USE Heat resistant polyurethane sealants which are not damaged by prolonged exposure to raised temperatures Many are flame resistant meaning that they...

Страница 3: ...NG LABEL INFORMATION When contacting your dealer for any cleaning service or warranty service always provide the Model Number Serial Number and Manufactured Date This information will expedite the war...

Страница 4: ...NISHING MATERIALS INSTALLATION 20 TILES AND FAUX ROCK 20 MARBLE AND GRANITE SLABS 20 HEARTH PROTECTION PAD REQUIREMENTS 21 GENERAL INFORMATION 22 GAS SUPPLY REQUIREMENTS 23 GAS SUPPLY LINE SIZING 23 G...

Страница 5: ...TRUCTIONS 64 INITIALIZING THE REMOTE CONTROL SYSTEM 64 IPI STANDING PILOT SYSTEM INFORMATION 65 INTERMITTENT PILOT LIGHT AND STANDING PILOT LIGHT FEATURES 65 SETTING TO IPI VERSUS CPI MODE 65 REPLACEM...

Страница 6: ...gases unless a certified kit is used Cet appareil peut tre install dans un maison pr fabriqu e mobile d j install e demeure si les r glements locaux le permettent Cet appareil doit tre utilis uniquem...

Страница 7: ...regular basis to make sure that no debris is interfering with the airflow The flow of combustion and ventilation air not to be obstructed DO NOT abuse the glass door by striking the glass slamming th...

Страница 8: ...State Building Code 3 A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a min imum height of eight 8 feet above grade directly in line with the ex...

Страница 9: ...e and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material carbon build up etc It is imperative that control...

Страница 10: ...Motor Blower System 120VAC 2Amps Dedicated Hot Power only No switches Fan Speed Controls or Light Dimmers are allowed in same circuit ACCENT LIGHT SYSTEM Accent Light System Included and can be turne...

Страница 11: ...LL 16in 40 5 cm UNIT TO ENCLOSURE SIDEWALL 1 2in 13mm VENT PIPE TOP TO COMBUSTIBLES 2in 51mm UNIT TO ENCLOSURE BACK WALL 1 2in 13mm VENT PIPE SIDES TO COMBUSTIBLES 1in 25mm UNIT TOP TO ENCLOSURE CEILI...

Страница 12: ...TAIL A A HEAT TRANSFER DUCT KNOCKOUT 6 5 8 X 4 COAXIAL STARTER COLLAR 32 1 4 ELECTRICAL SUPPLY INLET 110 VAC HOT NO SWITCH DC BACKUP POWER CORD 11 3 16 6 5 8 4 15 16 6 5 8 32 5 8 FINISHING GUIDE WIDTH...

Страница 13: ...HICKNESS 1 UNIT BASE TO ROOM CEILING MINIMUM DISTANCE 72 MINIMUM DISTANCE TO 8 MANTEL ABOVE UNIT BASE 48 5 8 14 5 8 ROUGH FRAMING DEPTH 40 5 8 ROUGH FRAMING WIDTH 16 MINIMUM TO SIDE WALL 135 ANY PROTR...

Страница 14: ...appliance on hard metal or wood surfaces extending full width and depth of this fireplace An R 1 Rated Hearth Protection Pad 1 1 2 Thick Maximum is required unless this fireplace is elevated at least...

Страница 15: ...al building codes MUST be adhered to Chases should be constructed in the manner of all outside walls of the home to prevent cold air drafting problems The chase should not break the outside building e...

Страница 16: ...m Fireplace Face the combustible mantel may pro trude outward at a Distance up From Floor Level of this Fireplace If you prefer to take measurements from the Top of the Convection Air Opening note tha...

Страница 17: ...atch the mounting height of this single gang box with the height of other AC outlets that are installed in the same room as this appliance WARNING DO NOT STAPLE the 6 DC Power Inlet Harness to the wal...

Страница 18: ...For more infor mation on what finishing guides to use reference the instructions that come with the decorative front RECOMMENDED BACKING MATERIALS OVER NON COMBUSTIBLE ZONES See R Ratings tables provi...

Страница 19: ...quality It is recommended that you use the highest R value rated material available and suitable for your particular type of Finishing Material and the attachment method you select to attach the Fini...

Страница 20: ...lished Rough Framing should be created at 14 1 8 depth with the front surface of this fireplace protruding out from the framing surface Install 1 2 thick drywall on framing members so that its outer s...

Страница 21: ...vated position by created an elevated deck and an appropriate framed enclosure NOTE This fireplace may be elevated but MUST allow a minimum of 72 distance between this fireplace s floor level and the...

Страница 22: ...floor and must extend a minimum of 18 in front of the fireplace For every 1 inch the fireplace is raised off the floor the depth of the hearth protector may be reduced by 2 inches If fireplace is rais...

Страница 23: ...er gas pipe diameters Strictly adhere to the correct pipe sizes PIPE LENGTH FEET SCHEDULE 40 PIPE INSIDE DIA TUBING TYPE L OUTSIDE DIA NAT L P NAT L P 0 10 1 2 1 3 cm 3 8 1 0 cm 1 2 1 3 cm 3 8 1 0 cm...

Страница 24: ...s capacity is not sufficient to add the Gas Fireplace an additional inches to inches regulator must be installed for the Fireplace EXCEPTION Some codes allow 2 PSI 1 4KPA supplies to enter the reside...

Страница 25: ...sure to also prepare opening to allow for co axial vent 2 Check to make certain all venting requirements and locations are being followed 3 This Fireplace is designed for installation into rough fram...

Страница 26: ...85 03 00988 26 P a g e NOTES...

Страница 27: ...ect Vent Fireplace it is critical that all brands of vent pipe sections are sealed tightly and leak proof This means that all pipe sections must be carefully rotated into the fully twist locked positi...

Страница 28: ...arance to ventilated soffit located above the terminal from the center line of the ter minal 24 60 cm min K Clearance to a mechanical air supply inlet 6 feet 1 8 m minimum E Clearance to unventilated...

Страница 29: ...rictions Flue Venting Components ITEM DESCRIPTION 1 6 or 7 PIPE DuraVent 6 Amerivent 7 9 12 2 12 VENT STACK 3 24 VENT STACK 4 36 VENT STACK 5 48 VENT STACK 6 90 GALVANIZED ELBOW 45 GALVANIZED ELBOW 7...

Страница 30: ...Maximum Horizontal run allowed with the minimum 18 vertical run is 6 3 Maximum Vertical Run allowed is 40 feet 4 Maximum Vent System length allowed is 40 feet 5 25 feet maximum horizontal run allowed...

Страница 31: ...gle 90 vertical to horizontal elbow is already calculated into the allowable maximum 25 horizontal run The Vent ing Requirements Chart assumes that for all horizontal runs calculated one 900 elbow is...

Страница 32: ...BOWS VERTICAL TERMINATION VERTICAL RISE DUAL 90 ELBOWS HORIZONTAL TERMINATION VERTICAL RISE TRIPLE 90 ELBOWS HORIZONTAL TERMINATION VERTICAL RISE TRIPLE 90 ELBOWS VERTICAL TERMINATION THREE HORIZONTAL...

Страница 33: ...or wall 3 Cut and frame a 9 wide x 10 high opening in the wall The hole must be positioned so the vent system will have a rise per foot of run AND be perpendicular to the wall The height of the open i...

Страница 34: ...utside wall Since vent pipe sections overlap we suggest pre assembling and measuring the total vent pipe run so you can more accurately locate the point where the vent pipe will penetrate the outside...

Страница 35: ...RISE DUAL 90 DEG ELBOWS HORIZONTAL TERMINATION V 2 MIN H1 H2 MAX 2 1 3 8 4 15 5 15 25 For V greater than 15 see Master Venting Chart VERTICAL RISE TRIPLE 90 DEG ELBOWS HORIZONTAL TERMINATION Use the...

Страница 36: ...st lock position and that inner pipe joints DuraVent only are sealed and are leak proof Maintain 1 airspace clearances to combustibles 2 above horizontal runs Cut a 9 x 10 opening in the roof centered...

Страница 37: ...85 03 00988 37 P a g e 40 FEET MAXIMUM STRAIGHT UP VERTICAL VENTING VERTICAL RISE DUAL 90 ELBOWS VERTICAL TERMINATION H V2 V1...

Страница 38: ...The use of Four 900 elbows must meet some minimum prerequisites Prerequisite 1 The vent system must terminate vertically using a vertical vent cap Prerequisite 2 There must be a minimum 3 feet of vert...

Страница 39: ...e and move away from unit 4 Door is now free from unit TO REPLACE DOOR 1 Line up the three bottom tabs in glass frame bottom with slots in glass clips on firebox bottom Insert tabs into slots and cent...

Страница 40: ...wire A powerful single blower is provided as standard equipment with this FV34 ARCH fireplace The blower has an air out put rating of 105 CFM in free air This fireplace is designed to operate with the...

Страница 41: ...Check for gas leaks and gas pressures prior to installing facing materials Install fresh batteries in remote transmitter Follow Initializing the System for the first time instructions to synchronize...

Страница 42: ...ttom foam trays It is of the utmost importance that you treat every package and every twig piece and assembly like you would an egg Breakage is your responsibility and is not covered by a Warranty Pol...

Страница 43: ...85 03 00988 43 P a g e PLACE LOG 1 REAR LOG ON REAR SHELF BEHIND REAR BURNER CENTER LOG ON THE AIRBOX PUSH LOG BACK SO IT TOUCHES REAR BRICK PANEL LOG 1...

Страница 44: ...S IF LOG 2 DOES NOT SIT BETWEEN REAR AND FRONT BURNER PLACE LOG 2 BETWEEN THE TWO BURNERS AND SLIDE TO THE RIGHT UNTIL THE CURVATURE IN THE FRONT BURNER CONTACTS THE CURVATURE ON THE RIGHT FRONT TIP O...

Страница 45: ...A NOTCH THAT MATES WITH THE LEFT MOST GRATE BAR SET LOG 3 ON THE GRATE BAR AND THE RECTANGLE SHAPED AIR SHUTTER BOX TOP SURFACE LOG 3 MUST LEAVE CLEARANCE FOR THE REAR BURNER PORTS SOME ROTATIONAL FLE...

Страница 46: ...OF LOG 4 ON TOP OF THE FIRST GRATE BAR ON THE FAR RIGHT SIDE SOME ROTATIONAL FLEXIBILITY IS ALLOWED TO LOG 4 AROUND THE PIN AND HOLE HOWEVER DO NOT ROTATE REAR END OF LOG OUTWARD ROTATE INWARD ONLY IF...

Страница 47: ...5 HAS A HOLE THAT ALIGNS WITH THE LEFT SIDE PIN ON LOG 1 THE V NOTCH BETWEEN THE TWO BRANCHES MUST SIT DIRECTLY ON TOP OF THE REAR BURNER S LEFT SIDE PORTS AND MUST ALLOW THE FLAMES TO RISE INTO THE V...

Страница 48: ...GHT SIDE OF LOG 1 LOG 6 HAS A HOLE IN ITS BACK SIDE TO MATE WITH THIS PIN PLACE LOG 6 ON TOP OF LOG 1 S PIN THE OTHER END OF LOG 6 SITS ON TOP OF LOG 2 AS SHOWN BELOW SOME ROTATIONAL FLEXIBILITY IS AL...

Страница 49: ...RESTS ON TOP OF THE FRONT BURNER S REAR VISIBLE EDGE AND ON TOP OF LOG 4 THIS LOG IS DESIGNED TO HIDE THE PILOT LIGHT PLACE THIS LOG SO IT PROVIDES CLEARANCE TO ALL BURNER FLAMES AND PILOT FLAMES YET...

Страница 50: ...THE BEST GLOW EFFECT AND REALISTIC LOOK DO NOT PINCH FRONT BURNER PORTS WITH LOG 8 LOG 9 RIGHT FRONT CHUNK IS TO BE PLACED AT A SEVERE ANGLE AGAINST THE HORIZONTAL GRATE BAR AND FLOATING OVER THE FRON...

Страница 51: ...85 03 00988 51 P a g e PLACE LOG 10 FAR RIGHT LOG ON THE FIREBOX FLOOR NEXT TO LOG 4 GRATE LOG 10 FIREBOX FLOOR GRATE LOG 10 FIREBOX FLOOR...

Страница 52: ...ND THE FRONT BURNER A FEW COALS MAY SIT ON TOP OF THE FRONT BURNER TUBE BUT AVOID PLACING TOO MANY COALS ON TOP OF THE FRONT BURNER PORTS USING A TOOTH BRUSH BRUSH INSWOOL GLOWING EMBERS RANDOMLY OVER...

Страница 53: ...gap on the right side of the Glass Door Frame Locate the Ring Terminal on the right side towards the bottom edge of the Glass Frame Insert Glass latch tool tip in the Ring Terminal s ring hole Slide...

Страница 54: ...shut off prior to disconnecting the electrical power ORIFICE SIZES REQUIREMENT A Natural Gas to LPG conversion kit HA 106 00023 must be ordered and installed in this fireplace insert to burn LPG LP Co...

Страница 55: ...box While holding the pilot base body with large vice grips tightly loosen Pilot Light s hex shape base using a open end wrench Ro tate counter clock wise turn to loosen 9 Pilot arrives from the facto...

Страница 56: ...er is running parallel to front face of unit positioned properly so that the pilot light hood pointing to the left is pointed properly towards the burner s flame propagation ports 14 Make certain Rear...

Страница 57: ...on the left side 17 Using a Torx T20 supplied or a slotted screwdriver remove 2 screws that secure the NG Pressure Regulator to the gas valve body and remove NG Pressure Regulator see following page...

Страница 58: ...URE REGULATOR CONVERSION INSTRUCTIONS WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifical ly approved with this appliance may result in prop...

Страница 59: ...completing the conversion process check for gas leaks with soap and water solution at all plumbing joints prior to placing this appliance into operation It is recom mended that all gas plumbing joints...

Страница 60: ...G and all the above steps have been completed light the main burners Use Remote Transmitter to turn on Pilot Light and burners Main burner should now light IMMEDIATELY and flame should not lift off bu...

Страница 61: ...ture Press the UP button until the desired temperature is displayed in the SET POINT TEMPERATURE window The fan will turn on 5 minutes after fireplace startup and will turn off 12 1 2 minutes after th...

Страница 62: ...lso extinguish If in Standing Pilot Mode the pilot light will remain ON Note If in SMART model the flame height function is not available for manual adjustment In SMART mode the flame height regulates...

Страница 63: ...eries used the number of ignitions of the appliance the number of changes to the room thermostat set point etc When the Transmitter bat teries are low a Battery Icon will appear on the LCD display of...

Страница 64: ...ts and the pilot is burn ing steadily 7 Once the pilot flame is lit and well established close glass door WARNING NEVER IGNITE MAIN BURNERS WITH GLASS DOOR REMOVED OR OPEN Doing so will lead to damage...

Страница 65: ...in the CPI Standing Pilot mode to allow the pilot light to remain on indef initely by setting the Remote Transmitter to CPI mode If the remote transmitter is set to the IPI Intermittent Pilot mode the...

Страница 66: ...3 8 TBE X 3 8MPT COMP ELBW 7 1 HA 81 00419 SHUTTER BOX SLIDER FV33i 8 2 65 06 00577 CABLE NUT ASSY 9 1 65 07 00010 BCF 3 8 TBE X 1 8MPT COMP ELBW AF 10 1 HA 81 00408 VALVE BRACKET FV33I 11 1 60 01 002...

Страница 67: ...1 Canadian Electrical Code Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and danger ous operation and Verify proper operation after servicing...

Страница 68: ...l components are available through Johnson Gas Appliance Company Con tact your dealer for more detailed ordering information GLASS FRAME ASSEMBLY HA 106 00001 REPLACEMENT PARTS LIST ITEM PART NUMBER D...

Страница 69: ...r tug on this harness which may result in breakage of connection terminals on either ends Convection Blower The convection blower is mounted on the firebox right wall Access to the convection blower i...

Страница 70: ...ology If the pilot flame is turned down too low the flame sensor may not de tect the pilot flame and the pilot light may not stay lit Do not turn down the pilot light flame The flame sensor rod may be...

Страница 71: ...ulb along top edge or sides are discolored to a white color appearance through the whole thickness of the gasket bulb then replace the gasket White colored gasket bulb indicates exhaust leak through t...

Страница 72: ...85 03 00988 72 P a g e NOTES...

Страница 73: ...used on inner joints at adjustable pipe sections CHECK FOR PROPER CLEARANCES TO COMBUSTIBLES VENT LOCATIONS Per Manual INSTALL PROPER SIZE GAS LINES CHECK FOR GAS LEAKS Per Manual CHECK FOR CORRECT GA...

Страница 74: ...85 03 00988 74 P a g e TAPE SHUT JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 POSTAGE NEEDED...

Страница 75: ...erial purchases that have not received prior written approval from Mendota NOTE Minor warping of certain parts or discoloration is normal and is not a defect covered by this warranty Major warping of...

Страница 76: ...85 03 00988 76 P a g e Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 Mendota Hearth Division WEBPAGE www johnsongas com or www mendotahearth com...

Отзывы: