![Mendota FV34-ARCH-PF2 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/mendota/fv34-arch-pf2/fv34-arch-pf2_installation-instructions-manual_1770799011.webp)
85-03-00988
11 |
P a g e
TECHNICAL SPECIFICATIONS FOR FV34-ARCH
High
Fire - Adjustable to -
Low Fire
BTUH. (MODEL FV34-ARCH)
NAT. GAS
31,500
8,985
BTUH. (MODEL FV34-ARCH)
LP GAS
31,500
12,627
NOTE: LPG CONVERSION KIT, HA-106-00023, MUST BE PURCHASED SEPARATELY
TO CONVERT TO BURN LPG IN THIS FIREPLACE.
MAIN ORIFICE [0-2000ft (610 m)]: REAR BURNER: #44 NG [3/64” L.P.] – FRONT BURNER: #49 NG [3/64“ LP]
........................ [2000-4500ft (610-1370 m)]: REAR BURNER: #44 NG [3/64” L.P.] – FRONT BURNER: #49 NG [3/64” LP]
OVERALL EFFICIENCY: ..................... P.4 FE 74.45%
CO-AXIAL DIRECT VENT FLUE: .......... 4" INNER, 6-5/8" OUTER
TOTAL WEIGHT: ................................... 220 POUNDS
SAFETY: ................................................ AGA/CECERTIFIED IPI AUTO ELECTRONIC IGNITION SYSTEM
ACTIVATED WITH THERMOSTATIC REMOTE CONTROL.
APPLIANCE CERTIFICATION AND TESTING AGENCY
INTERTEK TESTING SERVICES, ICBO#AA647-4
Certified under ANSI Z21.88 (2014)
CSA 2-33 (2014) “Vented Gas Fireplace Heaters" not for use with solid fuel. Approved for bed-
room installations and mobile homes. UL307B approved for "mobile homes, after first sale of home, not for recreational vehicles."
GLASS SAFETY BARRIER
A certified Glass Safety Barrier must be installed on this appliance during any use.
GAS REQUIREMENTS
.......................... SUPPLY PRESSURE:
GAS INLET: 1/2" N.P.T.
NAT.
GAS:
7" W.C.
(5" W.C. MIN., 11" W.C. MAX.)
L.P.
GAS:
11.0" W.C.
(11" W.C. MIN., 13" W.C. MAX.)
ELECTRICAL REQUIREMENTS
........... 115 VOLT, LESS THAN 1.5 amps (for blower operation only)
APPROVED VENT SYSTEMS
............... DURAVENT, SELKIRK, AMERIVENT, SECURITY
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION
UNIT
TO
FLOOR
0in.
(0mm)
INNER
GUIDE
EDGE TO ADJACENT SIDEWALL
16in. (40.5 cm)
UNIT TO ENCLOSURE SIDEWALL
1/2in. (13mm)
VENT PIPE TOP TO COMBUSTIBLES
2in. (51mm)
UNIT TO ENCLOSURE BACK WALL
1/2in. (13mm)
VENT PIPE SIDES TO COMBUSTIBLES
1in. (25mm)
UNIT TOP TO ENCLOSURE CEILING
1.5 in. (38 cm)
VENT PIPE BOTTOM TO COMBUSTIBLES
1in. (25mm)
UNIT BOTTOM TO ROOM CEILING
72 in. (182.9 cm)
8” MANTLE ABOVE DISCHARGE AIR OPENING
20 in. (508 mm)
MINIMUM COMBUSTIBLE ROUGH FRAMING DIMENSIONS (allow extra clearance for vent system)
WIDTH = 40-5/8” (103.2 cm)
HEIGHT = 40-3/4” (94 cm)
DEPTH = 14-5/8” (37 cm)
THIS FIREPLACE INCLUDES A SEALED COMBUSTION SYSTEM, 9-PIECE PREMIUM CERAMIC FIBER LOG SET & COALS,
FIREBRICK OR ENAMELED LINER LINED FIREBOX, NEO-CERAM GLASS, ELECTRONIC IGNITION SYSTEM, 110 CFM
CONVECTION AIR BLOWER, AGA CERTIFIED SAFETY SYSTEM, ACCENT LIGHT and THERMOSTATIC REMOTE CONTROL.
CAUTION
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE HOMEOWNER.
NOTE:
This installation must conform to local codes. In the absence
of local codes, you must comply with the
National Fuel Gas Code,
ANSI Z223.1-latest edition
in the U.S.A. and the Natural Gas and
Propane Installation Code,
CSA B149 Installation Codes
in Cana-
da.
This appliance may be installed in an
aftermarket, permanently located,
manufactured home (USA only) or
mobile home, where not prohibited
by local codes.
This appliance is only for use with
the type(s) of gas indicated on the
rating plate.
WARNING:
Do not operate this appliance with the glass removed,
cracked or broken. A licensed or qualified person should do re-
placement of glass.
HIGH ALTITUDE INSTALLATION INFORMATION
: Prior to installing at altitudes higher than 7500, understand
the need for gas input Deration. Contact Mendota Technical Service for support.
Содержание FV34-ARCH-PF2
Страница 26: ...85 03 00988 26 P a g e NOTES...
Страница 72: ...85 03 00988 72 P a g e NOTES...