FV34-ARCH
1'
2'
3'
4'
5'
10'
40'
35'
30'
25'
20'
2'
5'
10' 11'
17' 18' 20'
24' 25'
6"
1
8"
- MINIMUM 18" VERTICAL STARTER SECTION REQUIRED.
- MAXIMUM 6" HORIZONTAL RUN WITH 18" VERTICAL STARTER
SECTION ALLOWED.
- MAXIMUM 25 FEET HORIZONTAL RUN ALLOWED WITH
MINIMUM 5 FEET VERTICAL STARTER SECTION.
- MAXIMUM 40 FEET VERTICAL RUN ALLOWED.
- MAXIMUM 40 FEET VENT SYSTEM LENGTH ALLOWED.
- MAXIMUM 3 90° ELBOWS ALLOWED FOR HORIZONTAL
TERMINATION.
- MAXIMUM 4 90° ELBOWS ALLOWED FOR VERTICAL
TERMINATION.
10'
15'
FV34-ARCH MASTER FLUE VENTING REQUIREMENTS CHART
NOTE
: THIS CHART IS APPLICABLE TO BOTH NATURAL GAS AND LPG INSTALLATIONS.
1. 18 inches minimum vertical pipe run required to be connected directly to this fireplace’s flue starter collar.
2. Maximum Horizontal run allowed with the minimum 18” vertical run is 6”.
3. Maximum Vertical Run allowed is 40 feet.
4. Maximum Vent System length allowed is 40 feet.
5. 25 feet maximum horizontal run allowed with a minimum 5 to 15 feet starter section. If the starter vertical section is
less than 5 feet, use the chart and reduce 3 feet for every 90
0
elbow installed after the first 90
0
elbow.
6. 25 feet maximum horizontal run allowed only if the first vertical section connected directly to the top of this fireplace is
5 feet or longer. Three 90
0
elbows may be installed anywhere within the 25 feet horizontal run. For ALL horizontal
terminations, only 3 90
o
elbows allowed.
7. For ALL vertical terminations, four 90
o
elbows allowed. However, the 4
th
90
o
elbow must point vertically and directly to
the vent termination Cap.
V min
H max
18 in.
6"
24 in.
4’
36 in.
11’
48 in.
18’
60 in.
25'
5 ft. - 15 ft.
25'
15ft. - 40 ft. Varies
MASTER VENT CHART