background image

2

Height

Width

Depth

Total depth fron to back
including front section

Weight

External dimensions
Burcott

600mm

478mm

105mm

278mm

Building in dimensions
Burcott

510mm

390mm

180mm

80kg

Contents

BURCOTT

This manual refers to the stoves listed above, which are tested in accordance with EN 13240.

Thank you for purchasing your new stove from Mendip Stoves. Please read this manual carefully to ensure that you get

maximum enjoyment and performance from your new stove and to prevent any potential operational problems. Please note
that “all local regulations, including those referring to national and European Standards, need to be complied with when
installing this appliance”. For further information on installing and using fireplaces and wood burning stoves, please see the
relevant building regulations that apply to the country in which your stove is  installed and tested.

These instructions cover the basic principals to ensure the satisfactory installation of your  stove, although detail may need

slight modification to suit particular local site conditions.

ITEM

PAGE

Operation and installation manual

ENG

2-15

How to remove brickset ?
Exploded parts diagrams

ENG/FR

16-17

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Содержание Burcott Multi-fuel

Страница 1: ...Burcott Fireplace inset stove ENG FR OPERATION AND INSTALLATION MANUAL Multi fuel and SE models Guide d utilisation et Mode d Emploi...

Страница 2: ...blems Please note that all local regulations including those referring to national and European Standards need to be complied with when installing this appliance For further information on installing...

Страница 3: ...fitted in the same room as the appliance Further guidance on the installation of the carbon monoxide alarm is available in BS EN 50292 2002 and from the alarm manufacturer s instructions Provision of...

Страница 4: ...actory Alternatively the calculation procedure given in BS5854 1980 may be used as the basis for deciding whether a particular chimney design will provide sufficient draught If it is found that there...

Страница 5: ...liance from the opening 2e Using a masonry bit drill corresponding holes in the hearth and fit 1 x 6mm floor bolt 2f The appliance is now ready to be secured to the hearth afterthe flue system has bee...

Страница 6: ...ppliances can be affected by temporary atmospheric conditions which may allow fumes to enter the house Building regulations require that whenever a new or replacement fixed solid fuel or wood biomass...

Страница 7: ...STOVE DIMENSIONS AND CONNECTION MEASUREMENTS...

Страница 8: ...x 7cm x 6 cm Output wood fuel Efficiency CO 13 o2 Recommended for smoke control Oct 2014 Output coal fuel Efficiency CO 13 o2 Burcott 4 1kw 83 0 38 YES 3 9kw 79 0 36 Mendip Stoves Burcott models are...

Страница 9: ...oor of the combustion chamber HEARTH COMBUSTION AIR COMBUSTION CHAMBERS Mendip Stoves are fitted internally with vermiculite heat deflection panels and baffles these panels are designed to ensure the...

Страница 10: ...TIME Before lighting your stove for first time make sure you have read this manual fully and acquainted yourself with the controls of this appliance see page 9 The heat resistant paint on your stove w...

Страница 11: ...t closed To Open door lift handle To close push door closed and push handle down until located When opening the door of your Mendip stove always wear the glove that is provided to protect your hand fr...

Страница 12: ...e the primary slider again 6 Once established close the secondary air slider by 50 for the stove to burn cleanly plenty of secondary air is needed do not be tempted to shut the fire down too early as...

Страница 13: ...ld not be attempted Mendip smoke control stoves should not be burnt with the door left open The refuelling procedure allow the newly charged fuel to burn with the secondary air control set at maximum...

Страница 14: ...ed when operating air controls and door Re fueling solid fuel To re fuel your stove Before refuelling open Primary and secondary air controls to fully open Open door gently and de ash your stove with...

Страница 15: ...cleanly if it is burnt hotter Mendip stoves do not recommend that their stoves are burnt overnight for this reason As a night time regime we recommend that the fire is loaded when hot and burnt for fi...

Страница 16: ...there is an adequate air supply into the room e that an extractor fan is not fitted in the same room as the fire 2 Fire Blazing Out Of Control check a the doors are tightly closed b the air controls a...

Страница 17: ...le po le est en cours d utilisation Votre po le comprend les l ments suivants dans le po le This section shows the parts contained in your stove each stove has over 80 spare parts and each part is det...

Страница 18: ...Baffle plate and remove left front brick Then remove steel baffle plate This will leave the flue free for cleaning Fig 5 Slide rear brick to the left and remove Fig 3 Fig 4 Fig 1 Fig 2 Fig 5 Fig 1 Bur...

Страница 19: ...with the front right brick the front brick has a routed out section for the handle mount to fit see fig 9 Place the bricks back in the chamber as they where taken out Ensure the baffle is put back in...

Страница 20: ...Somerset BS26 2UG Tel 01934 750 500 Fax 01173 156 207 www Mendipstoves co uk E mail info mendipstoves co uk Distribu en France par la soci t Distributed in France and Benelux by Eurostove SAS Centre...

Отзывы: