background image

Always use the operating tools provided when

handling parts likely to be hot when the stove is
in use. Your stove  has the following  parts  in
the stove.

1.  Steel grate / log retainer
2.  Ash tray removal tool
3.  Ashpan
4.  Stove Glove
5.  Instruction manual & warranty card
6.  Vermiculite brick linings ( these are integral

to the stoves performance-Do not throw
away)

7.  Moisture absorbency bag

LOOSE PARTS / 

PIÈCES DÉTACHÉES

STOVE PARTS, COMBUSTION CHAMBER, ASSEMBLY

PIÈCES DÉTACHÉES, VUE ÉCLATÉES

1. Grille en fonte et arrêt de bûches
2. Outil pour retirer bac à cendre
3. Bac à cendre
4. Gant
6. Guide d’utilisation et bon de garantie
7. Briques réfractaires, elles font partie intégrante du poêle, ne
pas jeter.
8. Sac absorbant d’humidité

Toujours utiliser les outils prévus pour manipuler

les pièces susceptibles d'être chaudes lorsque le
poêle est en cours d'utilisation. Votre poêle
comprend les éléments suivants dans le poêle.

"This section shows the parts contained in your stove, each stove has over 80 spare-parts and, each part is detailed. When

new parts are required the section will allow spares  to be recognised and ordered. As a further source of reference
please visit www.eurostove.co.uk for latest spare-part information.

Cette section montre les pièces contenues dans votre poêle, chaque poêle a plus de 80 pièces de rechange et, chaque

élément est détaillée. Lorsque de nouvelles pièces doivent la section permettra aux pièces de rechange d'être reconnus
et ordonné. Comme autre source de refernece s'il vous plaît visiter pour www.eurostove.co.uk dernières informations
pièce de rechange.

Secondary air /air wash

Aire secondaire

Tertiary Air bar
Alimentation de l’air tertiaire

Vermiculite brick set

Jeu de plaques vermiculites

Steel grate
Grille en fonte

Log retainer

Arrêt de bûches

Steel (Baffle)
/Plate

Patte de support
pour déflecteur.

Содержание Burcott Multi-fuel

Страница 1: ...Burcott Fireplace inset stove ENG FR OPERATION AND INSTALLATION MANUAL Multi fuel and SE models Guide d utilisation et Mode d Emploi...

Страница 2: ...blems Please note that all local regulations including those referring to national and European Standards need to be complied with when installing this appliance For further information on installing...

Страница 3: ...fitted in the same room as the appliance Further guidance on the installation of the carbon monoxide alarm is available in BS EN 50292 2002 and from the alarm manufacturer s instructions Provision of...

Страница 4: ...actory Alternatively the calculation procedure given in BS5854 1980 may be used as the basis for deciding whether a particular chimney design will provide sufficient draught If it is found that there...

Страница 5: ...liance from the opening 2e Using a masonry bit drill corresponding holes in the hearth and fit 1 x 6mm floor bolt 2f The appliance is now ready to be secured to the hearth afterthe flue system has bee...

Страница 6: ...ppliances can be affected by temporary atmospheric conditions which may allow fumes to enter the house Building regulations require that whenever a new or replacement fixed solid fuel or wood biomass...

Страница 7: ...STOVE DIMENSIONS AND CONNECTION MEASUREMENTS...

Страница 8: ...x 7cm x 6 cm Output wood fuel Efficiency CO 13 o2 Recommended for smoke control Oct 2014 Output coal fuel Efficiency CO 13 o2 Burcott 4 1kw 83 0 38 YES 3 9kw 79 0 36 Mendip Stoves Burcott models are...

Страница 9: ...oor of the combustion chamber HEARTH COMBUSTION AIR COMBUSTION CHAMBERS Mendip Stoves are fitted internally with vermiculite heat deflection panels and baffles these panels are designed to ensure the...

Страница 10: ...TIME Before lighting your stove for first time make sure you have read this manual fully and acquainted yourself with the controls of this appliance see page 9 The heat resistant paint on your stove w...

Страница 11: ...t closed To Open door lift handle To close push door closed and push handle down until located When opening the door of your Mendip stove always wear the glove that is provided to protect your hand fr...

Страница 12: ...e the primary slider again 6 Once established close the secondary air slider by 50 for the stove to burn cleanly plenty of secondary air is needed do not be tempted to shut the fire down too early as...

Страница 13: ...ld not be attempted Mendip smoke control stoves should not be burnt with the door left open The refuelling procedure allow the newly charged fuel to burn with the secondary air control set at maximum...

Страница 14: ...ed when operating air controls and door Re fueling solid fuel To re fuel your stove Before refuelling open Primary and secondary air controls to fully open Open door gently and de ash your stove with...

Страница 15: ...cleanly if it is burnt hotter Mendip stoves do not recommend that their stoves are burnt overnight for this reason As a night time regime we recommend that the fire is loaded when hot and burnt for fi...

Страница 16: ...there is an adequate air supply into the room e that an extractor fan is not fitted in the same room as the fire 2 Fire Blazing Out Of Control check a the doors are tightly closed b the air controls a...

Страница 17: ...le po le est en cours d utilisation Votre po le comprend les l ments suivants dans le po le This section shows the parts contained in your stove each stove has over 80 spare parts and each part is det...

Страница 18: ...Baffle plate and remove left front brick Then remove steel baffle plate This will leave the flue free for cleaning Fig 5 Slide rear brick to the left and remove Fig 3 Fig 4 Fig 1 Fig 2 Fig 5 Fig 1 Bur...

Страница 19: ...with the front right brick the front brick has a routed out section for the handle mount to fit see fig 9 Place the bricks back in the chamber as they where taken out Ensure the baffle is put back in...

Страница 20: ...Somerset BS26 2UG Tel 01934 750 500 Fax 01173 156 207 www Mendipstoves co uk E mail info mendipstoves co uk Distribu en France par la soci t Distributed in France and Benelux by Eurostove SAS Centre...

Отзывы: