INFORMATION FOR THE USER, INSTALLER AND SERVICE ENGINEER

—----------------------------------------------------------------------------------------------------------------------------------------------------------------

Special care must be taken when installing a stove such that the requirements of the Health & Safety at Work Act are met.

Handling

Adequate facilities must be available for loading, unloading and site handling.

Fire Cement

Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case of contact
wash immediately with plenty of water.

PREPARATORY WORK AND SAFETY CHECKS

IMPORTANT WARNING

This stove must not be installed into a chimney that serves any other heating appliance. There must not be an extractor

fan fitted in the same room as the stove because this can cause the stove to emit fumes into the room.

Asbestos

This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the coarse of installation then please

seek specialist guidance and use appropriate protective equipment.

Metal Parts

When installing or servicing this stove care should be taken to avoid the possibility of personal injury.

CO Alarms:-

Building regulations require that whenever a new or replacement fixed solid fuel or wood/biomass appliance is installed in
a dwelling a carbon monoxide alarm must be fitted in the same room as the appliance. Further guidance on the
installation of the carbon monoxide alarm is available in BS EN 50292:2002 and from the alarm manufacturer’s
instructions.

Provision of an alarm must not be considered a substitute for either installing the appliance correctly or ensuring
regular servicing and maintenance of the appliance and chimney system.

Stove paint Aerosols
Paint aerosols are flammable and therefore dangerous to use around a lit stove. Be sure to allow  aerosols spray paints
to dry  and ventilate the room well  before lighting the stove. The use of any aerosol around lit stove is dangerous and
care must be take in handling aerosols.

IMPORTANT:

T

hese  instructions  cover  the  basic  principles  to  ensure  the  satisfactory  installation  of    Mendip  Stoves

product :-  Burcott, although detail may need slight modification to suit particular local site conditions.
In all cases the installation must comply with current Building Regulations, Local Authority Byelaws and
other specifications or regulations as they affect the installation of the stove.  It should be noted that the
Building  Regulations  requirements  may  be  met  by  adopting  the  relevant  recommendations  given  in
British  Standards  BS  8303,  BS  EN  15287  as  an  alternative  means  to  achieve  an  equivalent  level  of
performance to that obtained following the guidance given in Approved Document J.

HEALTH AND SAFETY PRECAUTIONS

Содержание Burcott Multi-fuel

Страница 1: ...Burcott Fireplace inset stove ENG FR OPERATION AND INSTALLATION MANUAL Multi fuel and SE models Guide d utilisation et Mode d Emploi...

Страница 2: ...blems Please note that all local regulations including those referring to national and European Standards need to be complied with when installing this appliance For further information on installing...

Страница 3: ...fitted in the same room as the appliance Further guidance on the installation of the carbon monoxide alarm is available in BS EN 50292 2002 and from the alarm manufacturer s instructions Provision of...

Страница 4: ...actory Alternatively the calculation procedure given in BS5854 1980 may be used as the basis for deciding whether a particular chimney design will provide sufficient draught If it is found that there...

Страница 5: ...liance from the opening 2e Using a masonry bit drill corresponding holes in the hearth and fit 1 x 6mm floor bolt 2f The appliance is now ready to be secured to the hearth afterthe flue system has bee...

Страница 6: ...ppliances can be affected by temporary atmospheric conditions which may allow fumes to enter the house Building regulations require that whenever a new or replacement fixed solid fuel or wood biomass...

Страница 7: ...STOVE DIMENSIONS AND CONNECTION MEASUREMENTS...

Страница 8: ...x 7cm x 6 cm Output wood fuel Efficiency CO 13 o2 Recommended for smoke control Oct 2014 Output coal fuel Efficiency CO 13 o2 Burcott 4 1kw 83 0 38 YES 3 9kw 79 0 36 Mendip Stoves Burcott models are...

Страница 9: ...oor of the combustion chamber HEARTH COMBUSTION AIR COMBUSTION CHAMBERS Mendip Stoves are fitted internally with vermiculite heat deflection panels and baffles these panels are designed to ensure the...

Страница 10: ...TIME Before lighting your stove for first time make sure you have read this manual fully and acquainted yourself with the controls of this appliance see page 9 The heat resistant paint on your stove w...

Страница 11: ...t closed To Open door lift handle To close push door closed and push handle down until located When opening the door of your Mendip stove always wear the glove that is provided to protect your hand fr...

Страница 12: ...e the primary slider again 6 Once established close the secondary air slider by 50 for the stove to burn cleanly plenty of secondary air is needed do not be tempted to shut the fire down too early as...

Страница 13: ...ld not be attempted Mendip smoke control stoves should not be burnt with the door left open The refuelling procedure allow the newly charged fuel to burn with the secondary air control set at maximum...

Страница 14: ...ed when operating air controls and door Re fueling solid fuel To re fuel your stove Before refuelling open Primary and secondary air controls to fully open Open door gently and de ash your stove with...

Страница 15: ...cleanly if it is burnt hotter Mendip stoves do not recommend that their stoves are burnt overnight for this reason As a night time regime we recommend that the fire is loaded when hot and burnt for fi...

Страница 16: ...there is an adequate air supply into the room e that an extractor fan is not fitted in the same room as the fire 2 Fire Blazing Out Of Control check a the doors are tightly closed b the air controls a...

Страница 17: ...le po le est en cours d utilisation Votre po le comprend les l ments suivants dans le po le This section shows the parts contained in your stove each stove has over 80 spare parts and each part is det...

Страница 18: ...Baffle plate and remove left front brick Then remove steel baffle plate This will leave the flue free for cleaning Fig 5 Slide rear brick to the left and remove Fig 3 Fig 4 Fig 1 Fig 2 Fig 5 Fig 1 Bur...

Страница 19: ...with the front right brick the front brick has a routed out section for the handle mount to fit see fig 9 Place the bricks back in the chamber as they where taken out Ensure the baffle is put back in...

Страница 20: ...Somerset BS26 2UG Tel 01934 750 500 Fax 01173 156 207 www Mendipstoves co uk E mail info mendipstoves co uk Distribu en France par la soci t Distributed in France and Benelux by Eurostove SAS Centre...

Отзывы: