SDM-9600 with SDM-9606 Blades Hardware Installation Guide
5-8
Memotec Inc.
5.5.2
System Status LEDs
The following system status LEDs are located on the front face of the SDM-9606 blade:
•
OOS
(Out Of Service; green/amber) goes on (green) when the blade is powered
on; turns amber when the card has failed in a chassis that has been powered on
•
ST
(Status, red/amber/green) indicates the current program status on the blade, as
shown in
Table 5-5
•
ALM
(Alarm; red/amber/green) indicates several alarm states, including a system
alarm when a software reset occurs. See
Table 5-6
•
H/S
(Hot Swap: blue), located on the right side of the blade, goes on and blinks
when the card handles are opened, indicating that the blade is
NOT READY
for
removal. The blade can be removed when this LED turns off. Refer to
“Remov-
ing a Blade” on page 4-12
.
The E1/T1 port status LEDS are described on
“E1/T1 Port Status LEDs” on page 5-16
.
State
Interpretation
Red
Early stages of system startup, when the
bootstrap program
is
running
Amber
Later stages of system startup, when the
boot sector
is running
Note:
The exact function that is taking place can be determined
in conjunction with the
ALM
LED. Refer to
Table 4-1
Off
System startup complete. The
application
is running but no link
is up
Green
The
application
is running and at least one link is up (specified
by the
T1/E1 PORT
LEDs)
Table 5-5: ST LED states
State
Interpretation
Green
Hardware initialization is in progress
Amber
A
Write
operation to Flash memory is in progress, e.g. decom-
pressing the application during startup, saving the application
after a download
Red
A software reset has occurred
Note:
To turn the
ALM
LED off, enter the
CE
(Clear ERR/DIAG
LED) command at the console command line.
Off
No alarm has occurred on the unit since the alarms were last
cleared
Table 5-6: ALM LED states
Содержание NetPerformer SDM-9600
Страница 1: ...NetPerformer SDM 9600 with SDM 9606 Blades Hardware Installation Guide...
Страница 6: ...Memotec Inc 7 4 Network Management and Security 7 5 Index 7...
Страница 8: ...Memotec Inc...
Страница 10: ...Memotec Inc...
Страница 11: ...1 Memotec Inc 1 1 Preface...
Страница 22: ...SDM 9600 with SDM 9606 Blades Hardware Installation Guide 1 12 Memotec Inc...
Страница 23: ...2 Memotec Inc 2 1 Compliance Information...
Страница 34: ...SDM 9600 with SDM 9606 Blades Hardware Installation Guide 2 12 Memotec Inc...
Страница 35: ...3 Memotec Inc 3 1 Unpacking the SDM 9600...
Страница 39: ...4 Memotec Inc 4 1 Hardware Installation...
Страница 63: ...5 Memotec Inc 5 1 Product Description...
Страница 81: ...6 Memotec Inc 6 1 Troubleshooting Tips...
Страница 84: ...SDM 9600 with SDM 9606 Blades Hardware Installation Guide 6 4 Memotec Inc...
Страница 85: ...7 Memotec Inc 7 1 Networking Features...
Страница 90: ...SDM 9600 with SDM 9606 Blades Hardware Installation Guide 7 6 Memotec Inc...
Страница 93: ...SDM 9600 with SDM 9606 Blades Hardware Installation Guide Index 9...