set
0
I
power
fresh air
0
1
2
3
4
5
6
alarm set
°C
UM 200-800/SM 200-400, ULM/SLM 400-800
12
With large ovens and heavy loads, the use of grates (option) is recommended instead of
the perforated shelfs.
In particular with heavy loads, the untested usage of these provisional values is not
sufficient. For a safe sterilisation, a validation of the individual sterilisation process must be
done, using e.g. additional temperature sensors or germ packets.
When sterilising the air flap has to be closed after the humid load has been dried.
Note: In case of a power failure the sterilising process may not be completed
properly. Therefore a permanent observation of the sterilising process or of
the mains supply is necessary to provide a safe sterilisation.
8.3 Notes on the work with sterilising cassettes:
The cassettes should be placed in the steriliser so that the hot air can flow easily through
the air ducts (in an steriliser with air turbine the airstream flows crosswise through the
working space). The directives about correct loading, which can be found in this operating
manual and on the steriliser have to be followed also when using sterilising cassettes. This
makes sure that a good temperature distribution is obtained and that the development of
cold air nests is prevented.
The sterilisation load must be packed in aluminium foil as shown in the table and must be
placed in the sterilising cassettes. The air ducts of the box
must be opened
for sterilising.
A temperature sensor for the verification of the temperature can be brought into the
sterilising cassette through opening 2.
After the sterilising time has elapsed, the air ducts
must be closed
by shifting knob 1 in
the direction of the arrow.
In this way, the sterilised goods can be preserved in the closed cassette for some days.
1
2
WARNING!
Models 700 and 800 are fitted with a door closure mechanism
incorporating a lock. If the user, against our express warning,
enters the interior of the steriliser it is essential that he first pulls
off the key and keeps it on his person.
Содержание SLM 400