1.3 

Target group

The activities described in this manual must only be carried out by technicians with the following 

qualifications:

 

Training in the installation and commissioning of electrical devices

 

Training in electrical hazards and the local safety requirements

 

Knowledge of the relevant standards and directives

 

Knowledge and observance of this document and all the safety instructions

1.4 

Revision index

Edition

Manual

Date

1

st

 edition

Installation manual M-WRG-S/Z-T(-F, -FC)

Week 50/2015 EN

1.5 

Explanation of the symbols used

 

This symbol indicates an action to be taken.

 

This symbol indicates a list.

1.6 

Supplementary documents

Manual

Part no.

Installation manual M-WRG-S.../M-WRG-K...

5300-10-01

2  Safety instructions

This manual contains notes that you must follow for your own personal safety and to avoid injury 

and damage to property. They are highlighted by warning triangles and are shown as follows ac-

cording to the level of danger.

2.1 

Hazard classification

DANGER

The signal word designates a hazard with a 

high

 degree of risk which, if it is not avoided, will result 

in death or severe injury.

WARNING

The signal word designates a hazard with a 

medium

 degree of risk which, if it is not avoided, will 

result in death or severe injury.

CAUTION

The signal word designates a hazard with a 

low

 degree of risk which, if it is not avoided, could 

result in minor or moderate injury.

NOTE

A note as used in this manual contains important information about the product or about a part of 

the manual to which particular attention should be paid.

Содержание InControl

Страница 1: ...eltem com VENTILATION THE RIGHT WAY VENTILATION HEAT RECOVERY INSTALLATION MANUAL HOME VENTILATION WITH HEAT RECOVERY M WRG S Z T F FC and InControl pushbutton sensor Connecting the ventilation unit M WRG S Z T F FC to the InControl pushbutton sensor Part no 5301 09 01 Week 50 2015 EN CO ...

Страница 2: ...l assignment 5 4 1 Board with terminal blocks 5 4 2 InControl pushbutton sensor 6 4 2 1 Back panel with terminal blocks 6 4 2 2 Connection diagram 6 5 Connecting one ventilation unit 7 5 1 Connecting the InControl pushbutton sensor to the M WRG S Z T ventilation unit 7 5 2 Connecting the InControl pushbutton sensor to the M WRG S Z T F ventilation unit 8 5 3 Connecting the InControl pushbutton sen...

Страница 3: ...aretaker or property manager These instructions are part of the product Keep the instructions in a safe place for future reference WARNING Follow ALL danger and warning instructions and notes on precautionary measures Read section 2 Safety instructions on page 4 carefully NOTE Also follow the M WRG S M WRG K installation manual part no 5300 10 01 for in stalling the ventilation units 1 2 Descripti...

Страница 4: ...en This symbol indicates a list 1 6 Supplementary documents Manual Part no Installation manual M WRG S M WRG K 5300 10 01 2 Safety instructions This manual contains notes that you must follow for your own personal safety and to avoid injury and damage to property They are highlighted by warning triangles and are shown as follows ac cording to the level of danger 2 1 Hazard classification DANGER Th...

Страница 5: ... intended use includes compliance with all the notes in the installation manual The ventilation unit must not be operated without a filter For any use contrary to the intended use Meltem Wärmerückgewinnung GmbH Co KG shall accept no liability for any damage that may occur and offers no warranty that the components will work perfectly and correctly 3 Warranty and liability The warranty and liabilit...

Страница 6: ...ation guide It is only in this position that the connections on the terminal blocks agree with the connec tions identified in the connection diagram Fig 4 4 2 2 Connection diagram Item Designation 1 Terminal block for pushbuttons 2 Terminal block for LEDs 3 Optional bridge for backlight NOTE The InControl pushbutton sensor has a backlight that can be acti vated if required Place a bridge item 3 in...

Страница 7: ...l pushbutton sensor Wire colour Function Pushbutton LED 1 GND GND 2 24 V DC 3 1 Reduced ventilation 4 2 Normal ventilation 5 3 Increased ventilation 6 4 Intensive ventilation 7 1 Reduced ventilation LED 8 2 Normal ventilation LED 9 3 Increased ventilation LED 10 4 Intensive ventilation LED 11 5 Supply air operation 12 6 Exhaust air operation 13 Unused 14 Unused 15 5 Supply air operation LED 16 6 E...

Страница 8: ...sensor Wire colour Function Pushbutton LED 1 GND GND 2 24 V DC 3 1 Reduced ventilation 4 2 Normal ventilation 5 3 Increased ventilation 6 4 Intensive ventilation 7 1 Reduced ventilation LED 8 2 Normal ventilation LED 9 3 Increased ventilation LED 10 4 Intensive ventilation LED 11 6 Supply air operation 12 Unused 13 5 Humidity control 14 Unused 15 6 Supply air operation LED 16 Unused 17 5 Humidity ...

Страница 9: ...button sensor Wire colour Function Pushbutton LED 1 GND GND 2 24 V DC 3 1 Reduced ventilation 4 2 Normal ventilation 5 3 Increased ventilation 6 4 Intensive ventilation 7 1 Reduced ventilation LED 8 2 Normal ventilation LED 9 3 Increased ventilation LED 10 4 Intensive ventilation LED 11 Unused 12 Unused 13 5 Humidity control 14 6 CO2 control 15 Unused 16 Unused 17 5 Humidity control LED 18 6 CO2 c...

Страница 10: ...t and InControl pushbutton sensor should be no more than 15 m long Ventilation unit 1 master must always be switched on It gener ates the feedback for the LED on the InControl pushbutton sensor Ventilation units 2 to 5 slaves only respond to switching commands from the InControl sensor NOTE Connect only to the first ventila tion unit master Connect GND to all the ventila tion units master slaves 6...

Страница 11: ... 4 4 4 4 3 5 5 5 5 5 4 6 6 6 6 6 5 13 13 13 13 13 6 11 11 11 11 11 GND 1 1 1 1 1 1 7 2 8 3 9 4 10 5 17 6 15 Table 5 Connecting the InControl pushbutton sensor to M WRG S Z T F ventilation units 6 3 Connecting the InControl pushbutton sensor to M WRG S Z T FC ventilation units Terminal blocks InControl pushbutton sensor Number M WRG S Z T FC ventilation unit Pushbutton LED 1 master 2 slave 3 slave ...

Страница 12: ...here may nevertheless still be differences so we cannot guarantee complete accuracy The information in this publication is regularly checked and any necessary corrections are made in the subsequent edi tions Copyright Meltem Wärmerückgewinnung GmbH Co KG We reserve the right to make changes Meltem Wärmerückgewinnung GmbH Co KG Am Hartholz 4 D 82239 Alling Germany Tel 49 0 8141 404179 0 Fax 49 0 81...

Отзывы: