Interfaces
Rev 1.1
Mellanox Technologies
51
Figure 31: MEX6200 with Transponder Protection
3.2.4
Fiber Protection
When an Optical Switch module is installed, its input is connected to the output of the MUX/
DEMUX module, and its two outputs are connected internally to two COM* ports.
The Optical Switch performs APS based on the received optical power level of the incoming
aggregated optical signal. Therefore, the Optical Switch can be used to protect against cable
break, but not against uplink transceiver failure.
The facility protection ensures service continuity in case of a fiber break. The fiber protection
based on the Optical Switch module is supported only for point-to-point topologies.
The following figure shows an Optical Switch Protection application.
Figure 32: Fiber Protection with Optical Switch
When an Optical Switch is installed, the COM1 and COM2* buttons are shown and enabled in
the Web application. In this case, the protection is done on the entire optical signal, which
includes all channels.
The following figure shows the front panel of the MEX6200 as displayed in the Web application.
Figure 33: MEX6200 with Optical Switch
*The COM2 port is currently out of use.
Содержание MetroX TX6240
Страница 1: ...www mellanox com Mellanox MetroX Long Haul Systems Hardware User Manual Models TX6240 TX6280 Rev 1 1...
Страница 8: ...Mellanox Technologies 8 Table 37 RJ 45 CONSOLE Pinout 72 Table 38 RJ 45 I2C Pinout 72...
Страница 79: ...Rev 1 1 Mellanox Technologies 79 5 6 7 8 9 10...
Страница 80: ...Mellanox Technologies 80 11 12 13 14 15 16...
Страница 81: ...Rev 1 1 Mellanox Technologies 81 17 18 19 20 21 WEEE 22...
Страница 83: ...Rev 1 1 Mellanox Technologies 83 7 8 9 10 InfiniBand 11 12 13 PSU InfiniBand...
Страница 96: ...Mellanox Technologies 96 4 5 6 7 8 9 10 InfiniBand 45 C 113 F 8 3 InfiniBand...
Страница 97: ...Rev 1 1 Mellanox Technologies 97 11 12 13 14 15 16 UL CSA UL CSA 3 16 AWG 1 5 6 4 5 125 13 HAR 3 1 0 300 250 10...