Installation
Rev 1.1
Mellanox Technologies
31
2.8
Initial Power On
2.8.1
TX6240/TX6280 Initial Power On
The system’s input voltage is auto-adjusting for 100 - 240VAC, 50-60Hz power connections. The
power cords should be standard 3-wire AC power cords including a safety ground and rated for
15A or higher.
Step 1.
Plug in the first power cable.
Step 2.
Plug in the second power cable.
Step 3.
Wait for the system upload process.
Step 4.
Check the System Status LEDs and confirm that all of the LEDs show status lights consistent
with normal operation, as shown in Figure 21 below. For more information, refer to “LEDs” on
page 52.
Caution: The system platform will automatically power on when AC power is
applied. There is no power system. Check all boards, power supplies, and fan tray
modules for proper insertion before plugging in a power cable.
This unit is intended for installation in a Restricted Access Location. A restricted
access area can be accessed only through the use of a special tool, lock and key, or
other means of security.
Do not plug the cords to power supplies yet.
It may take up to five minutes to turn on the system. If the System Status LED shows
red after five minutes, unplug the system and call your Mellanox representative for
assistance.
Содержание MetroX TX6240
Страница 1: ...www mellanox com Mellanox MetroX Long Haul Systems Hardware User Manual Models TX6240 TX6280 Rev 1 1...
Страница 8: ...Mellanox Technologies 8 Table 37 RJ 45 CONSOLE Pinout 72 Table 38 RJ 45 I2C Pinout 72...
Страница 79: ...Rev 1 1 Mellanox Technologies 79 5 6 7 8 9 10...
Страница 80: ...Mellanox Technologies 80 11 12 13 14 15 16...
Страница 81: ...Rev 1 1 Mellanox Technologies 81 17 18 19 20 21 WEEE 22...
Страница 83: ...Rev 1 1 Mellanox Technologies 83 7 8 9 10 InfiniBand 11 12 13 PSU InfiniBand...
Страница 96: ...Mellanox Technologies 96 4 5 6 7 8 9 10 InfiniBand 45 C 113 F 8 3 InfiniBand...
Страница 97: ...Rev 1 1 Mellanox Technologies 97 11 12 13 14 15 16 UL CSA UL CSA 3 16 AWG 1 5 6 4 5 125 13 HAR 3 1 0 300 250 10...