Installation
Rev 1.1
Mellanox Technologies
24
2.4.2
MEX6200 Mounting
2.4.2.1 Rack Kit Contents
Figure 11: Rack Installation Kit
2.4.2.2 Rack Installation
To mount the MEX6200 unit:
Step 1.
Attach the left and right mounting brackets (shown in Figure 12) to the unit, by fastening the 8
screws provided in the package, as illustrated in Figure 13. Note that each of the brackets can
be shifted by 6cm, inside or outside.
Figure 12: Rack Mount Brackets
In case you are required to transfer the MEX6200 WDM unit after the rack mount
installation is complete, please remove the system from the rack and ship it separately.
In no case should you ship the MEX6200 installed in a rack mount.
1 x Rack mount 19" left
1 x Rack mount 19" right
8 x Flat Phillip 6-32X1/4 screw
4 x M6 Pan head Phillips screw
4 x M6 Cage nut
1 x Flat washer
1 x Fiber tray