MAINTENANCE
6-9
MA-5130-GBR
PS20 NON STOP DRUM UNLOADER INHIBITION MANUAL
4. The amplifier that adjusts the sensor´s sensitivity is located in the control
cabinet.
This amplifier has two states indicated with two different LED colours (1):
• Green: no adhesive (empty).
• Yellow: there is adhesive (full).
5. Remove the plastic plug of the amplifier to access the sensitivity ad-
justment potentiometer (2) and turn the adjusting screw at least 3 turns
counterclockwise. The LED must be green.
6. With the sensor still covered by melted adhesive, gently turn the adjusting
screw clockwise, just until the LED turns yellow (sensor activated).
7. Gently turn the adjusting screw ¼ turn counterclockwise. The LED will
change back to green.
Verification of the sensor regulation
1. Increase slightly the adhesive level of the tank. The LED should change to
yellow.
2. Decrease the adhesive level of the tank. As soon as the detector is visible,
the LED should change to green.
It is recommended to carry out a verification of the signals once the equip-
ment is in automatic operation.
In Non Stop melters, check which cylinder pushes the adhesive block when
the amplifier LED shows the green colour and stops pushing when it is yellow
colour
1
1
2
2
Empty
Full
Содержание PS20
Страница 1: ...GLUING SOLUTIONS MA 5130 GBR 221220 ADHESIVE MELTER PS20 NON STOP INHIBITION INSTRUCTIONS MANUAL ...
Страница 15: ...INTRODUCTION 2 5 MA 5130 GBR PS20 NON STOP DRUM UNLOADER INHIBITION MANUAL 10 11 9 12 7 8 1 2 3 6 4 13 5 5 ...
Страница 18: ...FOCKE MELER GLUING SOLUTIONS 2 8 INTRODUCTION This page is intentionally left blank ...
Страница 30: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 12 This page is intentionally left blank ...
Страница 56: ...FOCKE MELER GLUING SOLUTIONS 4 26 NAVEGATION SUR L ECRAN TACTILE Cette page n a pas de texte ...
Страница 80: ...FOCKE MELER GLUING SOLUTIONS 7 4 TECHNICAL CHARACTERISTICS This page is intentionally left blank ...
Страница 81: ...ELECTRICAL DRAWINGS 8 1 MA 5130 GBR PS20 NON STOP DRUM UNLOADER INHIBITION MANUAL 8 ELECTRICAL DRAWINGS ...
Страница 82: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 84: ...FOCKE MELER GLUING SOLUTIONS 9 2 PNEUMATIC DRAWING 1 2 3 4 9 8 5 6 7 16 17 19 18 10 11 12 13 14 15 ...
Страница 86: ...FOCKE MELER GLUING SOLUTIONS 9 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Страница 88: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...
Страница 96: ...FOCKE MELER GLUING SOLUTIONS 10 10 SPARE PARTS LIST 3 27 1 2 21 6 10 9 4 7 5 20 22 ...