
INSTALLATION
3-7
MA-5130-GBR
PS20 NON STOP DRUM UNLOADER INHIBITION MANUAL
External ON/OFF
1. If only this signal will be connected, use a 0.5 mm
2
two-wire cable.
2. Open the door of the electrical cabinet as far as possible. Thread the
power cord (Ø4-8 mm) through the electrical cable gland Pg13, making
sure that the cord reaches the terminal blocks where that signal has to
be connected.
3. Disconnect the jumper cables between terminals
13X21
y
13X22
.
4. Insert the wires in
13X21
and
13X22
terminals blocks and tighten
them with the fixing screws. The terminal block is double so you must
to connect every wire in a free hole of the terminal block. It has no
polarity so it doesn’t matter the place you connect them.
5. Make sure that the cables are firmly attached by the terminal screws.
6. Make sure that the cable is well connected and that its path through
the electrical cabinet presents no risks of snagging, being cut or any
other accidental deterioration.
External Standby
1. If only this signal will be connected, use a 0.5 mm
2
two-wire cable.
2. Open the door of the electrical cabinet as far as possible. Thread the
power cord (Ø4-8 mm) through the electrical cable gland Pg13, making
sure that the cord reaches the terminal blocks where that signal has to
be connected.
3. Insert the wires in 13X11 and 13X12 terminal blocks and tighten them
with the fixing screws. The terminal block is double so you must
to connect every wire in a free hole of the terminal block. It has no
polarity so it doesn’t matter the place you connect them.
4. Make sure that the cables are firmly attached by the terminal screws.
5. Make sure that the cable is well connected and that its path through
the electrical cabinet presents no risks of snagging, being cut or any
other accidental deterioration.
Warning:
It must be connected to 24 AC or DC voltage with a maximum
current of 1A.
Low level (optional)
1. If only this signal will be connected, use a 0.5 mm
2
two-wire cable.
2. Open the door of the electrical cabinet as far as possible. Thread the
power cord (Ø4-8 mm) through the electrical cable gland Pg13, making
sure that the cord reaches the terminal blocks where that signal has to
be connected.
3. Insert the wires in 16X57 and 16X58 terminal blocks and tighten them
with the fixing screws. The terminal block is double so you must
to connect every wire in a free hole of the terminal block. It has no
polarity so it doesn’t matter the place you connect them.
Содержание PS20
Страница 1: ...GLUING SOLUTIONS MA 5130 GBR 221220 ADHESIVE MELTER PS20 NON STOP INHIBITION INSTRUCTIONS MANUAL ...
Страница 15: ...INTRODUCTION 2 5 MA 5130 GBR PS20 NON STOP DRUM UNLOADER INHIBITION MANUAL 10 11 9 12 7 8 1 2 3 6 4 13 5 5 ...
Страница 18: ...FOCKE MELER GLUING SOLUTIONS 2 8 INTRODUCTION This page is intentionally left blank ...
Страница 30: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 12 This page is intentionally left blank ...
Страница 56: ...FOCKE MELER GLUING SOLUTIONS 4 26 NAVEGATION SUR L ECRAN TACTILE Cette page n a pas de texte ...
Страница 80: ...FOCKE MELER GLUING SOLUTIONS 7 4 TECHNICAL CHARACTERISTICS This page is intentionally left blank ...
Страница 81: ...ELECTRICAL DRAWINGS 8 1 MA 5130 GBR PS20 NON STOP DRUM UNLOADER INHIBITION MANUAL 8 ELECTRICAL DRAWINGS ...
Страница 82: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 84: ...FOCKE MELER GLUING SOLUTIONS 9 2 PNEUMATIC DRAWING 1 2 3 4 9 8 5 6 7 16 17 19 18 10 11 12 13 14 15 ...
Страница 86: ...FOCKE MELER GLUING SOLUTIONS 9 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Страница 88: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...
Страница 96: ...FOCKE MELER GLUING SOLUTIONS 10 10 SPARE PARTS LIST 3 27 1 2 21 6 10 9 4 7 5 20 22 ...