MA-5195-ENG
PS20 NON STOP+ DRUM UNLOADER MANUAL
MELTER OPERATION
4-9
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
10 min
85 °C
60 s
Modbus
B: 57600
Node: 10
2.2 Extra Settings
Inside device temperature alarm
Pumping autolock
Screen saver
Sound on alarm
OFF after reset
White: editable text.
Blue: non-editable text.
Interpretación de las pantallas
!
Save changes
The ‘SAVE CHANGES’ icon, located in the upper right part of the screen,
appears in the data entry and programming screens. If the data shown on the
screen is stored, the icon appears with a blue background. If the data has not
been stored, the icon is shown with a green background.
Note:
In some options, the unit does not automatically store programming
data. Whenever you modify or program any data that you wish to keep press
“SAVE CHANGES”.
Press to save
Parameters saved
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
30
12
300
P:
I:
D:
-60 °C
150 °C
152 °C
PID: Standard
Standby
Temperature:
Real
Set Point
T: Tank
!
General characteristics
In general, there are several icons and pieces of information that are repeated
throughout the screen navigation, so they will be explained at the beginning
and then not in the next screens.
Navigation icons
Right arrow icon (FORWARD), located in the lower right part of the screen.
Appears when there is a possibility of navigation to a next screen. From the
HOME screen it provides access to the MENU.
Left arrow icon (BACK), located in the lower left part of the screen. This icon
appears on all the menu screens, allowing you to return to the previous
screen.
From any screen you can return to the main screen by clicking on the icon
(HOME) located in the bottom centre of the screen.
White: editable parameter.
Grey: non-editable parameter.
Green: activated.
White: deactivated.
Grey: disabled.
Green: press to save.
Blue: parameters saved.
Alphanumeric
keyboard
Numeric keyboard
BACK
HOME
FORWARD
Содержание PS 20 NON STOP+
Страница 1: ...GLUING SOLUTIONS MA 5195 ENG 010620 ADHESIVE MELTER PS20 NON STOP INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 68: ...FOCKE MELER GLUING SOLUTIONS 4 42 MELTER OPERATION This page is intentionally left blank ...
Страница 80: ...FOCKE MELER GLUING SOLUTIONS 6 2 TECHNICAL CHARACTERISTICS Dimensions ...
Страница 81: ...ELECTRICAL DRAWINGS 7 1 MA 5195 ENG PS20 NON STOP DRUM UNLOADER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 82: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 84: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWING 16 17 19 18 10 11 12 13 14 15 ...
Страница 86: ...FOCKE MELER GLUING SOLUTIONS 8 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Страница 88: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...