FOCKE MELER GLUING SOLUTIONS
5-4
MAINTENANCE
5 Once completely empty, clean the any remaining adhesive from around
the output hole and chute.
6 Replace the plug.
7 Raise the emptying chute and replace the side shroud cap.
Warning:
Use appropriate protective equipment for high temperatures.
Cleaning the bottom of tank
It is often necessary to clean the bottom tank to remove PUR impurities on the
walls.
To do so, follow these instructions:
1 Remove the front and rear covers.
2 Remove the screws holding the side cover. The tank and distributors
should be completely accessible.
Содержание PS 20 NON STOP+
Страница 1: ...GLUING SOLUTIONS MA 5195 ENG 010620 ADHESIVE MELTER PS20 NON STOP INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 68: ...FOCKE MELER GLUING SOLUTIONS 4 42 MELTER OPERATION This page is intentionally left blank ...
Страница 80: ...FOCKE MELER GLUING SOLUTIONS 6 2 TECHNICAL CHARACTERISTICS Dimensions ...
Страница 81: ...ELECTRICAL DRAWINGS 7 1 MA 5195 ENG PS20 NON STOP DRUM UNLOADER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 82: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 84: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWING 16 17 19 18 10 11 12 13 14 15 ...
Страница 86: ...FOCKE MELER GLUING SOLUTIONS 8 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Страница 88: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...