INTRODUCTION
Pneumatic by-pass valve pressure control system (VP)
The inlet pressure at the bypass valve is regulated by the proportional valve,
which is commanded by an external signal (0-10V signal).
By defect, the conversion is the following:
0 V --> 0 pneumatic bars
10 V --> 6 pneumatic bars
With this operating mode, the pressure at the bypass automatically varies, and
so on, the quantity of adhesive applied.
It is important to keep a minimum pump speed in order to maintain the
demanded adhesive.