![Meler Macro Series Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/meler/macro-series/macro-series_instruction-manual_1767094064.webp)
FOCKE MELER GLUING SOLUTIONS
5-6
MAINTENANCE
Warning
: Use appropriate protective equipment for high temperatures.
Pump maintenance
Inspecting for leaks
The pump is equipped with a gasket system on the shaft to prevent adhesive
from leaking through it. On occasion, some adhesive may leak out, which
makes it necessary to retighten the screws or change the gasket.
Warning
: Changing the gasket with a hot pump.
Release the shaft coupling from the pump. Retighten or remove the screws
that hold the gasket in place. Replace the gaskets and reassemble the parts.
Occasionally, as a result of the system’s heating-cooling cycles, it may be
necessary to retighten the screws.
Warning
: Always wear protective gloves and goggles. Risk of burns.
Motor-gear maintenance
Cleaning the motor fan
Periodically inspect the condition of the motor fan and its vent screen.
If dust has accumulated, blow gently with air to clean it (remove the protective
cover, if necessary).
Checking the lubricant
The gear reducers are delivered filled with synthetic grease for lubrication
-free of outside contamination- ‘for life’. Ambient temperature 0 ÷ 40 °C, with
peaks of as low as -20 °C and up to +50 °C.
Use only those lubricants recommended by the manufacturer. The use of other
types may cause premature wear or damage to the gear reducer.
If the unit features a 0.375 kW gear motor, its gearbox will have a capacity for
approximately 0.19 kg of lubricating grease. In the case of 0.55 kW, 0.75 kW
and 1.1 kW gear motors, the gearboxes need at least 1.1 litres of lubricating
oil.
Содержание Macro Series
Страница 1: ...MA 5052 ENG 221220 GLUING SOLUTIONS ADHESIVE MELTER MACRO SERIES INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 16: ...FOCKE MELER GLUING SOLUTIONS 2 4 INTRODUCTION Main components 10 10 12 14 13 11 15 1 2 3 7 6 8 9 4 5 5 ...
Страница 32: ...FOCKE MELER GLUING SOLUTIONS 3 12 INSTALLATION This page is intentionally left blank ...
Страница 58: ...FOCKE MELER GLUING SOLUTIONS 4 26 MELTER OPERATION This page is intentionally left blank ...
Страница 66: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 6 4 TECHNICAL CHARACTERISTICS This page is intentionally left blank ...
Страница 71: ...ELECTRICAL DRAWINGS 7 1 MA 5052 ENG MACRO SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 72: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 74: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...
Страница 82: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST This page is intentionally left blank ...