4-23
MELTER OPERATION
MA-5052-ENG
MACRO SERIES MELTER MANUAL
Notes on the editable values in the conversion table:
• The value for voltage must always be shown to one decimal place.
• Point 1 is the starting point for the
speed ramp, and therefore the
voltage will always be 0, while the value for output RPM is editable.
• The possible values for each point must be equal to or greater than the
value corresponding to the previous point.
• Point 5 is the final point for the speed ramp, and therefore the voltage
will always be 10, while the value for output RPM is editable.
• It is not necessary to program the value for MAXIMUM RPM in this table.
• If, at any point, the maximum value for Vin = 10 V is entered, the
corresponding values for Vin and RPM at higher points will be
automatically updated according to the value for this point.
• If, at any point, the maximum value is entered, that is, RPM =
MAXIMUM RPM, the corresponding values for RPM at higher points will
be automatically updated to MAXIMUM RPM.
Programming speed ramp
To access this menu and program the different points corresponding to the
voltage-speed ratio, you must select external reference (‘ref ext’ LED is
illuminated) and press the right arrow key. Then the following message is
displayed:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 1 000,
NOT EDITABLE;
press the right arrow to go to the next point:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 1 XXX,
which means that the output speed is being programmed for point 1 (when the
input voltage is 0 V); with the up/down arrow keys the value may be modified,
within a range from 000 to MAXIMUM RPM; press the right arrow key to go to
the next point:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 2 XXX
,
which means that the input voltage value is being programmed for point 2;
with the up/down arrow keys the value may be modified, within a range from
00.0 to 10.0 (to one decimal place); press the right arrow key to go to the next
point:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 2 XXX,
which means that the output speed value is being programmed for point 2;
with the up/down arrow keys the value may be modified, within a range from
Содержание Macro Series
Страница 1: ...MA 5052 ENG 221220 GLUING SOLUTIONS ADHESIVE MELTER MACRO SERIES INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 16: ...FOCKE MELER GLUING SOLUTIONS 2 4 INTRODUCTION Main components 10 10 12 14 13 11 15 1 2 3 7 6 8 9 4 5 5 ...
Страница 32: ...FOCKE MELER GLUING SOLUTIONS 3 12 INSTALLATION This page is intentionally left blank ...
Страница 58: ...FOCKE MELER GLUING SOLUTIONS 4 26 MELTER OPERATION This page is intentionally left blank ...
Страница 66: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 6 4 TECHNICAL CHARACTERISTICS This page is intentionally left blank ...
Страница 71: ...ELECTRICAL DRAWINGS 7 1 MA 5052 ENG MACRO SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 72: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 74: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...
Страница 82: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST This page is intentionally left blank ...