MAINTENANCE
Removing and changing exterior panels:
1. Disconnect the melter equipment.
2. Disconnect the compressed air from the equipment intake.
3. Turn counterclockwise 1/4 turn the two screws holding the panel.
4. Tilt the panel and pull it up by means of two handles placed below
fixing screws.
5. To replace the panels, follow steps 1 through 4 in the reverse order.
Depressurizing the system
Melting equipment belonging to the Macro system series include a safety
valve (a by-pass valve) that limits the maximum pressure within the system,
especially during continuous pumping periods with closed applicator
applicators.
However, even with the motor turned off, residual pressure may exist in the
circuit. This must be kept in mind when performing any operation on the
hydraulic circuit.
Before disconnecting any hydraulic element or opening any distributor outlet,
it is necessary to perform the following steps:
1. Disconnect the equipment switch located on the front.
2. Operate the purge valve housed in each distributor to free any residual
pressure from the circuit.
3. Manually purge (or use the corresponding control command) all the
applicators that have been used.
Filter maintenance
Pump filter
Macro system series melter equipment is equipped with a 50 mesh pump
filter. The filter prevents impurities and burnt adhesive remains from being
pushed out from the tank by the pump.
The adhesive flows from the inside to the outside of the filter, with impurities
being trapped inside it.
When the filter is removed from its housing, all the impurities remain trapped
inside, and the inside of the distributor stays perfectly clean. The filter may be
cleaned or replaced directly with a new one.
Содержание Macro Series
Страница 1: ...MA 5052 ENG 221220 GLUING SOLUTIONS ADHESIVE MELTER MACRO SERIES INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 16: ...FOCKE MELER GLUING SOLUTIONS 2 4 INTRODUCTION Main components 10 10 12 14 13 11 15 1 2 3 7 6 8 9 4 5 5 ...
Страница 32: ...FOCKE MELER GLUING SOLUTIONS 3 12 INSTALLATION This page is intentionally left blank ...
Страница 58: ...FOCKE MELER GLUING SOLUTIONS 4 26 MELTER OPERATION This page is intentionally left blank ...
Страница 66: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 6 4 TECHNICAL CHARACTERISTICS This page is intentionally left blank ...
Страница 71: ...ELECTRICAL DRAWINGS 7 1 MA 5052 ENG MACRO SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 72: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 74: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...
Страница 82: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST This page is intentionally left blank ...