![background image](http://html1.mh-extra.com/html/melec/gd-5510-01/gd-5510-01_instruction-manual_1767064016.webp)
GD-5510-01
Instructions Manual
4-3.Setting STEP ANGLE SELECT switch
Erroneous setting may cause breakage of
the machine or injury due to unexpected
rotation of motor.
Ensure correct setting.
The step angle is set up with the STEP SEL switch.
The step angle can be selected from ten different
types of step angles.
The switch is factory-set to [No.1].
(1)
Set the STEP SEL switch No. to the step angle required.
● Relationship between the STEP SEL switch No. and the step angle.
(Factory setting)
● Driving with two types of step angles are provided by combining
the STEP SEL switch setting and the C.S signal.
1/800
Step angle(°)
0.72°motor
0.72
0.36
1/100
1/200
1/400
0.18
0.072
8
9
Number of
Divisions
1/1
1/2
1/4
1/10
1/20
1/40
5
6
7
Switch
No.
1
2
3
4
0
0.0018
0.0009
0.036
0.018
0.0072
0.0036
I
-16-