4.Function Set-up by Use
4-1.Setting STEP ANGLE SELECT switch
Erroneous setting may cause breakage of
the machine or injury due to unexpected
rotation of motor.
Ensure correct setting.
The step angle is set up with the STEP SEL switch.
The step angle can be selected from six different
types of step angles.
(1)
Set the step angle required by the STEP SEL switch [SA,SB,SC].
●Relationship between the STEP SEL switch and the step angle.
(Factory setting)
OFF
OFF
OFF
-
-
OFF
OFF
ON
-
-
OFF
ON
OFF
1/32
0.05625
OFF
ON
ON
1/16
0.1125
ON
OFF
OFF
1/8
0.225
ON
OFF
ON
1/4
0.45
ON
ON
OFF
1/2
0.9
ON
ON
ON
1/1
1.8
STEP SEL switch
1/
Divisions
Step angle(°)
SC
SB
SA
1.8°motor