4.Function Set-up by Use
4-1.Setting STEP ANGLE SELECT switch
Erroneous setting may cause breakage of
the machine or injury due to unexpected
rotation of motor.
Ensure correct setting.
The step angle is set up with the STEP SEL switch.
The step angle can be selected from four different
types of step angles.
Set this switch power OFF.
The switches are factory-set to [1/32 divisions].
(1) Turn power [OFF].
(2)
Set the STEP SEL switch [SA,SB] to the step angle required.
●Relationship between the STEP SEL switch and the step angle.
(Factory setting)
STEP SEL switch
Number of
Divisions
Step angle(°)
SB
SA
1.8°motor
ON
ON
1/2
0.9
ON
OFF
1/8
0.225
OFF
ON
1/16
0.1125
OFF
OFF
1/32
0.05625
I