- 13 -
C-VX875
Instructions Manual
No.
Item
Description of specifications
3 Other
Input signal logical switch ・The input signal can be changed to logic as follows:
functions
function
・CWLM
・CCWLM
・DALM
(INx is used for DALM function)
Input signal time constant
・The input signal can be set time constant as follows:
function
・CWLM
・CCWLM
・DALM
(INx is used for DALM function)
・DEND/PO
・ORG
・NORG
・±ZORG
・±EA,EB
Multipurpose sensor
Each axis has multipurpose sensor signal input used as
signal input
stop signal, trigger signal of a counter latch data
and drive CHANGE operating signal.
The signal can be used as multipurpose sensor as
follows:
・SENSORx input signal
・SIGNAL INx input signal
・A status in any axis
Status external signal
・The compare register value, STATUS, output signal
output function
of each counter can output as SIGNAL OUTx output
signal.
Synchronized start
・You can perform synchronized start with any axis.
function
・A condition of start can be set by the condition as
follows:
・SENSORx input signal
・SIGNAL INx input signal
・A status in any axis
・PAUSE command
Status read
・Current status information can be read in real time.
Data reading
・Current status information includes setting data
any axis, latch
data of a counter etc.
※ Applied function.
Refer to the separate manual of the Windows device driver corresponding to C‑VX875 Applied Functions