Copyright © 2018 Meitrack Group All rights reserved. - 6 -
Note: The alert results vary according to the device installation, vehicle model, vehicle weight, and driving
behaviors. After the device has been installed properly, you can use the Meitrack Manager software to adjust the
harsh acceleration and braking alert values by every 10 mG. You can also use the D79 command to set the values.
2.1.2
GPS Data Filtering
The GPS data filtering function can ensure GPS data accuracy and eliminate static drift.
You can set the following parameters by Meitrack Manager:
GPS speed range
,
GPS positioning accuracy
, and
Number of GPS satellites
. When the GPS data filtering function is enabled, if all conditions are met, GPS data will
be updated.
Note: This function can be enabled by Meitrack Manager.
2.1.3
Activating Output by Event
You can activate output by event.
For example:
1.
When speeding is detected, the buzzer will make sounds.
2.
When unauthorized ignition or GPS antenna cut-off is detected, the engine will not be able to start.
3.
When iButton triggering is detected, the device can control engine startup.
4.
When input or output status is detected, the output will be active or inactive.
2.1.4
Idling Detection
This function is used to detect whether a vehicle's engine is switched off while parking. To enable the function, you
must connect input 2 to ACC detection.
When the device detects that the driving speed is 0 and the ACC is on for one consecutive minute (default time), an
idling alert will be generated.
For details, see section 6.5.7 "Setting Idling Time – D34."
2.1.5
Changing I/O Port Mode
This function is used to change the I/O port mode. For example, change active negative input to analog port or