MEITRACK T1 User Guide
Copyright © 2018 Meitrack Group All rights reserved. - 17 -
1
Red
Power output
Output voltage: 5 V
2
Black
Ground wire
3
Orange
RX, T1 receives data from the S microphone.
4
Yellow
TX, T1 sends data to the S microphone.
5
Blue
Positive charge of the microphone
6
Green
Negative charge of the microphone
7
Purple
Positive charge of the speaker
8
White
Negative charge of the speaker
Note: The RS232 port can be used with either the RFID reader or the camera at a time.
8.4
Installing the RFID Reader (RS232 Port)
Pin Number
Color
Description
1
Red
Power output
Output voltage: 5 V
2
Black
Ground wire
3
Green
RX, T1 receives data from the RFID reader.
4
White
Reserved (TX, T1 sends data to the RFID reader.)
Remarks: The T1 RFID reader is not compatible with the MVT600 RFID reader. In the MVT600, the RS232 port
is a Wiegand port.
Note: The RS232 port can be used with either the S microphone or the camera at a time.
8.5
Installing the Camera (RS232 Port)
Pin Number
Color
Description