background image

3

 

05.13 Ref. 201067 Rev. 101 

SWITCH S1 

Fan in Saving Mode 

Compressor 

temporization 

Modes 

Window contact 

FAN. 

AUTO 

FAN. 

ALWAYS 

ON 

4 Min. 

delay 

Wthout 

delay 

(test) 

Only cool 

Heat Pump or 

Cooling with 

heating stage 

Off System 

Change to 

economy 

mode 

S1.1 

OFF 

ON 

S1.2 

OFF 

ON 

S1.3 

OFF 

ON 

S1.4 

UNUSED 

S1.5 

UNUSED 

S1.6 

OFF 

ON 

SWITCH S2

 

Ambient temperature sensor 

Modes 

Internal sensor 

(in remote) 

External sensor 

Only cool or 

cool with 

heating stage 

Heat Pump 

(V4V) 

S2.1 

ON 

OFF 

S2.2 

OFF 

ON 

S2.3 

ON 

OFF 

S2.4 

OFF 

ON 

SWITCH S2

 

In screen 

Cooling with heating 

stage config. 

Heat pump config. (V4V) 

Ambient 

temperature 

Order 

temperatura 

Electric 

resistance 

Combustible 

Activate in 

heat 

Activate in 

cool 

S2.5 

OFF 

ON 

OFF 

ON 

S2.6 

ON 

OFF 

4. Operation Manual

4.1 Switch on / Switch off 

Press button ON/OFF to switch on / switch off the thermostat

The words "ON" or "OFF" will display on the screen.

4.2 Temperature adjustment 

Adjustment the order temperature using the buttons “+” or “-”

switch on  

  switch off 