Scheme Terminal assignment
Programmable Pulses
Four programmable outputs (PP 1 - PP 4)
DC-insulated by optocouplers
U
CEmax
= 55 V
I
Cmax
= 50 mA
P
tot
= 150 mW
Response time
Turn on Time: typ. 5
µ
s, max. 9
µ
s
Turn off Time: typ. 10
µ
s, max. 70
µ
s
Standard (Opto Coupler)
Channel 4
Channel 2
Channel 1
PP 4
PP 2
PP 1
PP 3 +
PP 1 +
Pulse generator
PP 2 +
Channel 3
PP 3
PP 4 +
Error Relay
The X1 connector has a potential-free contact which is
controlled directly by the used reference clock (GPS,
GNS, GNS-UC). Normally, when the reference clock
has synchronized, the the relay contact "NO" switch to
active. If the reception is disturbed or the device is
switched off, the relay contact "NC" is active.
Technical Specification
Switching Voltage max:
60 V DC
Switching Current max:
I
max
:
400mA
Switching Load max:
24 W
Response Time:
ca.2ms
Normal Operation Mode:
CO - NO connected
(normally open)
(normally closed)
Error Mode:
CO - NC connected
NO
NC
CO
PP
1
2
3
4
NO
NC
CO
PP
1
2
3
4
24
Date: January 7, 2022
microSync
Содержание microSync HR100/DC
Страница 1: ...TECHNICAL REFERENCE microSync HR100 DC January 7 2022 Meinberg Funkuhren GmbH Co KG ...
Страница 2: ......