8 Starting of Operation
8.1 Initial Network Configuration
After the system has been connected to the power supply and to the receivers antenna, the initial setup can be
started. The device starts immediately after connection to the power supply.
A microSync system is delivered with a static configured IP address. The DHCP service is deactivated. This
means that you have to establish a manual network connection to be able to configure system settings.
To configure a microSync system you need the Meinberg Device Manager software. This tool is provided
on the supplied USB stick. You can always download the latest version from our website:
https://www.meinbergglobal.com/english/sw/mbg-devman.htm
If the network settings of your PC do not allow a connection to the microSync system, you have to adjust
the settings of your network adapter. At delivery the microSync system has the following network settings:
IP v4 address
192.168.19.79
Netmask:
255.255.255.0
Gateway:
This entry is empty
DHCP:
disabled
Username:
admin
Password:
timeserver
If you do not have access to the properties of the
network adapter due to security restrictions, you can
also use an USB - Ethernet adapter (not included in
delivery scope), where you can edit and change the
network properties.
Change the settings of your network adapter so that
you can establish a network connection with the mi-
croSync system. All further settings can now be done
with our Meinberg Device Manager software.
microSync
Date: January 7, 2022
33
Содержание microSync HR100/DC
Страница 1: ...TECHNICAL REFERENCE microSync HR100 DC January 7 2022 Meinberg Funkuhren GmbH Co KG ...
Страница 2: ......