Note: A bit configured for output can be read back!
1)
Parameter of the function …
:
<BitNumber>
Select the multi-I/O bit wanted.
<Direction>
Choose between input or output.
<Invert>
The polarity of an input can be inverted.
<Interrupt>
Bit becomes an edge triggered interrupt
input. Condition is that the bit will be configured as
input. The interrupt is directly forwarded to the system.
All enabled interrupt bits initiate one common interrupt
of the digital-I/O section (IRQ-DIO). The single bit cannot
be determined as the interrupt source.
2)
Parameter of the function …
<OutputMode>
A bit configured for output can also set
to a high-impedance state (tristate).