ME-9000(i/p)*/8
RS485
PCI/PCIe/cPCI
8
RS-485 ports up to 921,6
kBd
ME-9000(i/p)*/2
MIX
PCI/PCIe/cPCI
1
RS-232 port and 1 RS-485
ports up to 921,6
kBd
ME-9000(i/p)*/8
MIX
PCI/PCIe/cPCI
4
RS-232 ports and 4 RS-485
ports up to 921,6
kBd
* The PCI-Express models, the ME-9000 PCI models (from Rev. 1.4 up)
and the ME-9000 CompactPCI models (from Rev. 1.2 up) are
provided with optional opto-isolation from PC ground („i“-models)
resp. with electrical insulation between the single ports („p“-models).
Note: Further versions on request (
).
The ME-9000 series is a high integrated serial interface board
designed for PCI-, PCI-Express- resp. CompactPCI-bus. It provides
a PCI controller with integrated Octo-UART of type EXAR
XR17D158IV for extended temperature range. The UARTs are
register-compatible with the 16550 and provide an integrated 64-
byte transmit and receive FIFO for each port. The board allows
transfer rates up to 921,6 kBd. There are versions available with
up to 8 ports for RS-232 and/or RS-422/485 standard. The ME-
9000 PCI- and cPCI-versions adapt themselves automatically to
the level at the PCI bus of +3.3 V or +5 V (Universal PCI).
As a special the ME-9000 offers an 8-bit multi-I/O port for
customer-specific extensions. See also chapter 4.1 "ME-9000
Multi-I/O Driver" from page 61 on.
The ME-9000i models provide opto-isolation of all serial ports from
PC ground. I.e. as seen from the application all ports refer to a
common, isolated ground (GND_C). The isolation voltage is 500 V.
ME-9000p models: each serial port is an electrically isolated
„island“ with separate ground (GND_x). It is ideal for noise-
sensitive environments in industrial control. The isolation voltage is
500 V.
Содержание ME-90 Series
Страница 30: ...3 2 Block Diagram ME 9100 2 4 or 8 RS 232 and or RS 422 485 ports depending on version...
Страница 31: ...3 3 Block Diagram ME 9300 8 or 16 RS 232 ports depending on version...
Страница 35: ......
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 39: ...3 5 2 ME 9100 PCI...
Страница 40: ...3 5 3 ME 9100 CompactPCI...
Страница 68: ......
Страница 105: ...B2 ME 9000 9100 RS 422 485 see note on page 111...
Страница 112: ...B8 9 pin male connector ME 90 PC 104 Plus B9 8 pin RJ 45 female connectors...
Страница 113: ...B10 Null modem cable see note on page 111 not for ME 90 PC 104 Plus...