CashFlow
9520 / 9524 / 9528 Design Guide
MEI., 2003
Page
17
Rev: G1
Coin Validation Inhibits A, B, C, D, E, F
To inhibit coin acceptance the CashFlow
®
validator offers six individual inhibit inputs.
These inhibits operate for each mode as detailed in the following text.
Binary Coded Output Mode Inhibits - UK
The channels inhibited, for a given inhibit line becoming active are factory set by the
validator coin inhibit map option. When inhibit (A to F) is active, then coins for the channels
specified in the map will be inhibited. The default settings for the GB profile are:
Inhibit Line
Coins inhibited
A
£2
B
Token
C
Reserved
D
20p
E
5p, 10p, 50p old & new
F
£1
Binary Coded Output Mode Inhibits - Euro
(BCO - EURO) Coin Inhibit
Coin
No.
Value
A
B
C
D
E
F
Coin 1
Token 1
1
X
Coin 2
Token 2
1
X
Coin 3
1c
1*
X
Coin 4
2c
1*
X
Coin 5
5c
1*
X
Coin 6
10c
1*
X
Coin 7
20c
1*
X
Coin 8
50c
X
1
Coin 9
1Eu
X
1
Coin 10
2EU
X
1
Coin 11
5Eu
1*
X
X= RESERVED
*= GROUPED INHIBIT INPUT
Содержание CASHFLOW 9520
Страница 1: ...MEI 2003 Rev G1 CASHFLOW 9520 9524 9528 SELECTOR SYSTEMS DESIGN GUIDE...
Страница 33: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 33 Rev G1...
Страница 34: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 34 Rev G1...
Страница 35: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 35 Rev G1...
Страница 36: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 36 Rev G1...
Страница 37: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 37 Rev G1...
Страница 38: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 38 Rev G1...
Страница 39: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 39 Rev G1...
Страница 48: ...CashFlow 9520 9524 9528 Design Guide HELPING YOU DELIVER YOUR REPRESENTATIVE...