CashFlow
9520 / 9524 / 9528 Design Guide
MEI., 2003
Page
24
Rev: G1
Connector 4, Dynamic Route Inhibit
This input from the host machine to the front reject cover of the validator is known as the
Dynamic Route Inhibit. This inhibit signal indicates that a specific route has become full. To
Inhibit a route the relevant pin should be grounded (i.e. active low to inhibit a route).
Connector type used:- 9 pin SIL - AMP 925366.
Route Inhibit Connector
Pin No.
CF9528
8 Way Separator Exit Route
CF9524
4 Way Separator Exits
1
Route 1
Exit (d) = 1
2
Route 2
Exit (c )= 2
3
Route 3
Exit (a) = 3
4
Route 4
Exit (b) = 4
5
Route 5
Exit C = 5
6
Route 6
Exit D = 6
7
Route 7
Exit B = 7
8
Route 8 is the Default
Exit A is the Default
9
Ground (0v)
Ground (0v)
Note: Care must be taken to apply a Route full signal to the correct pin. For example of
Exit D is selected then the signal should be directed to Pin 6 (D). Likewise Pin 1 (d) should
be used of Primary Route (d) is selected.
Содержание CASHFLOW 9520
Страница 1: ...MEI 2003 Rev G1 CASHFLOW 9520 9524 9528 SELECTOR SYSTEMS DESIGN GUIDE...
Страница 33: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 33 Rev G1...
Страница 34: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 34 Rev G1...
Страница 35: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 35 Rev G1...
Страница 36: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 36 Rev G1...
Страница 37: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 37 Rev G1...
Страница 38: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 38 Rev G1...
Страница 39: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 39 Rev G1...
Страница 48: ...CashFlow 9520 9524 9528 Design Guide HELPING YOU DELIVER YOUR REPRESENTATIVE...