(BCO - EURO) Coin Output

Coin

No.

Value

A

B

C

D

E

F

Coin  1

Token  1

1

0

1

0

0

0

Coin  2

Token  2

1

0

1

0

0

1

Coin  3

1c

1

0

1

0

1

0

Coin  4

2c

1

0

1

0

1

1

Coin  5

5c

1

0

1

1

0

0

Coin  6

10c

1

0

1

1

0

1

Coin  7

20c

1

0

1

1

1

0

Coin  8

50c

1

0

1

1

1

1

Coin  9

1Eu

1

1

1

0

0

0

Coin  10

2EU

1

1

1

0

0

1

Coin  11

5Eu

1

1

1

0

1

0

Vending

The BCO codes operate in a similar way to those used in Italy.  Coin output A is active to
indicate to the machine that the Acceptor is in BCO Mode.  Coin output E is active when a
correct code is given to the machine. This effectively becomes the Parity used by the
machine to authenticate that a current shown code is correct. This should be used in Even
Parity.  Coin outputs B, C, E and D become the 4 code states indicating which coin is
accepted.

(BCO - EURO) Coin Output

Coin

No.

Value

A

B

C

F

D

E

Coin  1

1c

1

1

0

0

0

1

Coin  2

2c

1

0

1

0

0

1

Coin  3

5c

1

1

1

0

0

0

Coin  4

10c

1

0

0

1

0

1

Coin  5

20c

1

1

0

1

0

0

Coin  6

50c

1

0

1

1

0

0

Coin  7

1Eu

1

1

1

1

0

1

Coin  8

2EU

1

0

0

0

1

1

Coin  9

5Eu

1

1

0

0

1

0

Содержание CASHFLOW 9520

Страница 1: ...MEI 2003 Rev G1 CASHFLOW 9520 9524 9528 SELECTOR SYSTEMS DESIGN GUIDE...

Страница 2: ...r distributed in any form or by any means or stored in a database or retrieval system or translated in any language natural or computer without the prior written permission of MEI Mars CashFlow and th...

Страница 3: ...TOR 10 13 PRE GATE STROBES 11 13 VALIDATOR LID 12 13 PRODUCT INTERFACES 14 STANDARD INTERFACES 14 PARALLEL MODE 14 MULTI PULSE 14 COIN VALIDATION INHIBITS A B C D E F 14 PARALLEL OUTPUT MODE INHIBITS...

Страница 4: ...OUTPUT BCO 31 COIN INHIBITS 31 MECHANICAL INTERFACE DRAWINGS 32 CF9524 FRONT PLATE DIMENSIONS 32 CF9524 TOP ENTRY MOUNTING SPACE ENVELOPE 32 CF9528 LONG CHANNEL MOUNTING SPACE ENVELOPE 32 COMPATIBILI...

Страница 5: ...ective units according to local regulations Conformance to International Standards When installed and operated according to the instructions provided for the particular unit CashFlow products meet the...

Страница 6: ...l compatibility The products detailed in this handbook relate to the CashFlow 952x Series To ensure you have the right product for your application please read this section CashFlow 9520 Supports 4 wa...

Страница 7: ...e assembly This front plate is made of mild steel painted black and is a standard assembly suitable for internal mounting It is not supplied with a coin catcher hoop This model consists of the same pa...

Страница 8: ...s are routed to the bottom centre of the reject cover This type of reject cover is used on validators that are fitted to small channels Accepted coins are routed to the right and down Rejected coins a...

Страница 9: ...MEI 2003 Page 9 Rev G1 Product Build Options Each product variant is made from the following components Side Entry Product 7802 Front Plate 7804 Front Plate 7805 Front Plate 7819 Front Plate Side Ent...

Страница 10: ...ge 10 Rev G1 Top Entry Product 4 way Separator Coin Entry Token Entry Bezel with electrics CF9524 8 Y Chute CF9524 8 Top Entry Validator Metal Channel CF9528 Short Channel Supplied by machine manufact...

Страница 11: ...Memory Contacts 4 Support Tool Connector CPM CashFlow Programming Module 5 Route Inhibit Connector 6 Serial Interface Connector HII 7 Separator Connector 8 8 way DIP Switch 9 Post Gate Strobes 10 Dua...

Страница 12: ...but not accepted due to inhibit setting i Button Memory Contacts 3 This connector enables the i button to communicate with the product i button activity is indicated by the illumination status of the...

Страница 13: ...tive common Binary Coded Output BCO These will be automatically selected by the Output mode select line if nothing is connected to the output line then the acceptor will default to parallel mode Pre G...

Страница 14: ...GB profile four times on validation of a GB 2 coin Coin validation Inhibits A B C D E F To inhibit coin acceptance the CashFlow validator offers six individual inhibit inputs These inhibits operate di...

Страница 15: ...D E F 5p 1 0 1 0 0 0 10p 1 1 1 1 0 0 20p 1 0 1 0 1 1 50p Old 1 1 1 0 0 1 50p New 1 0 1 1 0 1 1 1983 1 1 1 0 1 0 2 1 1 1 1 1 1 Token 1 0 1 1 1 0 Alarm Output 1 1 0 1 1 1 Binary Coded Output BCO Euro G...

Страница 16: ...aly Coin output A is active to indicate to the machine that the Acceptor is in BCO Mode Coin output E is active when a correct code is given to the machine This effectively becomes the Parity used by...

Страница 17: ...ory set by the validator coin inhibit map option When inhibit A to F is active then coins for the channels specified in the map will be inhibited The default settings for the GB profile are Inhibit Li...

Страница 18: ...ded output interface standards A logic high signal to this pin will select parallel mode setting pin 8 to a logic low will select BCO mode If there is no connection made to pin 8 the interface will de...

Страница 19: ...Dual Polarity GB Coins Input or Output PIN No BCO Function Definition 1 A Coin Output 5p O 1 Ident signal 2 1 B Coin Output Token O 2 Accept Output 5 3 2 Coin Output Common I 3 Accept Output Common 4...

Страница 20: ...it a route plug into the separator Route Input Lines Routes 1 7 The CF9528 exit routes are marked as Route 1 2 3 4 5 6 7 with 8 being the default exit route as standard Routes 1 7 on CF9528 refer to t...

Страница 21: ...ut Coin D 8 Output Mode Select 9 Output Coin C 10 Inhibit Coin C 11 Power in 12v 12 Ground 0v 13 Inhibit Coin D 14 Inhibit Coin E 15 Inhibit Coin F 16 Inhibit Coin B 17 Inhibit Coin A Dynamic route in...

Страница 22: ...ng a MEI support tool e g CPM CashFlow Programming Module Serial HI2 Connector 10 way The position of this connector has been moved from the previous CF126 product and can now be found on the front fa...

Страница 23: ...The product defines the exit depending on the type being set as primary or secondary Example If the chosen Primary Route a the only Secondary routes available can only be b C D or B Therefore d and c...

Страница 24: ...route Connector type used 9 pin SIL AMP 925366 Route Inhibit Connector Pin No CF9528 8 Way Separator Exit Route CF9524 4 Way Separator Exits 1 Route 1 Exit d 1 2 Route 2 Exit c 2 3 Route 3 Exit a 3 4...

Страница 25: ...ace is not supplied with the single entry system Pin No Function Input Output Notes 1 12 Volts Output 12 volts supply to the validator 2 Inhibit F Output Inhibit signals to the validator 3 Inhibit E O...

Страница 26: ...e host machine interface wiring as shown below Validator Interface Y Chute Interface Machine Coin Inhibits Y Chute Inhibits Coin Outputs Dual Entry System Coin and Token and power and power With singl...

Страница 27: ...e only 800 mA 2 Routing Solenoids 2 300 mA for 320mS 3 Routing Solenoids 3000 mA for 320 mS Coin Output Electrical Specification Output Circuit Block Diagram Vcc 4k7 1K 56R 10n Logical Outputs A B C D...

Страница 28: ...tions However the minimum turn on time when output common was floating is 15 micro seconds If the polarity is established on output common by means of a weak pull up for ve com or pull down ve com the...

Страница 29: ...ten involved in a coin mechanism interfaces it is recommended that the input should be de bounced in software to avoid glitches Coin Inhibits High Coin inhibit Low Coin enable Maximum input voltage to...

Страница 30: ...Output Common Voltage 7 volts to 26 volts with respect to pin 12 Positive Common Outputs On Maximum current 40mA Saturation voltage Output common Coin O P 1 5V Off 10uA maximum at 27 volts Output comm...

Страница 31: ...dicator can take up to 100 milliseconds to be established from power up In order to ensure reliable operation of the machine the state of this output should be regularly polled as the coin validator c...

Страница 32: ...Drawing Number 32799 Standard front plate dimensions Drawing Number 35811 Side entry space envelope CF9524 Top Entry Mounting Space Envelope Drawing Number 35812 CF9528 Long Channel Mounting Space Env...

Страница 33: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 33 Rev G1...

Страница 34: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 34 Rev G1...

Страница 35: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 35 Rev G1...

Страница 36: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 36 Rev G1...

Страница 37: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 37 Rev G1...

Страница 38: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 38 Rev G1...

Страница 39: ...CashFlow 9520 9524 9528 Design Guide MEI 2003 Page 39 Rev G1...

Страница 40: ...Flow 9520 9524 9528 Design Guide MEI 2003 Page 40 Rev G1 COMPATIBILITY Previously Used New Product Equivalent CashFlow 111 CashFlow 115 CashFlow 9520 CashFlow 126 CashFlow 9524 CashFlow 129 CashFlow 9...

Страница 41: ...335 1 3rd Edition Safety of household and similar electrical appliances Part 1 General Requirements b BS3456 Safety of household and similar electrical appliances Part 1 General Requirements c BS EN60...

Страница 42: ...edges which can prevent a hazard in normal use Coin Sizes CashFlow 9524 and CashFlow 9528 will be able to validate and route coins within the following range Circular coins in the range 15mm to 31 5 m...

Страница 43: ...0 C Storage range 10 C to 75 C Max rate of change 10 C hr non condensing Humidity Range Operational 10 RH 90 RH non condensing Storage 5 RH to 95 RH non condensing Temperature Humidity specification 1...

Страница 44: ...of performance For continuous operation and specified performance within the full operational temperature range the rate of change of temperature should not be greater than 10 C per hour non condensi...

Страница 45: ...apply to fully packaged units Shock Half sine 30g shock 18ms dur BS 2011 Part 2 1 EA 1977 Bump 1000 bumps 6ms duration at 25g BS 2011 Part 2 1 b 1977 Drop Free Fall 2 drops from 1m onto each face BS...

Страница 46: ...GmbH Alter Teichweg 63 22049 Hamburg Contact Andre Schreiert Tel 49 40 6918581 Fax 49 40 6929194 AUTOMATEN TECHNIK SCHREIERT GmbH Niederlassung S d Baindterstra e 46 2 88255 Baienfurt Contact Herr Rom...

Страница 47: ...Reixac Barcelona Contact Javier Pineda Tel 34 93 564 7800 GREAT BRITAIN BRENT Electronic Namco House Acton Park Estate The Vale London W3 7QE Contact Peter Murphy Tel 020 8324 6212 Fax 020 8324 6125 G...

Страница 48: ...CashFlow 9520 9524 9528 Design Guide HELPING YOU DELIVER YOUR REPRESENTATIVE...

Отзывы: