8. To stop the test press 

TEST

button.

9. Timer will stop. 

10. Analogue display shows insulation resistance.

11. Digital display shows resistance or current selected by pressing 

/I 

button.

12. Load capacitance will be calculated and displayed after the end of 

the test.

13. Time-constant will be displayed after the end of the test.

INSTRUMENT CONTROLS AND INDICATORS

5

1. Check connections to load  - see 

SAFETY WARNINGS

2. To turn on, press Power On/Off button and release after display 

responds. The instrument first will perform a self-check during which 

Ini is displayed. After Ini disappears the instrument is ready for use.

3. Check voltage at terminals display to be sure the load is safe to 

energise.

4. Set test voltage required with V

s

and V

t

buttons.

5. To start a test, press 

TEST

button and release after red LED shows. If 

external voltage at terminals <50 V, testing starts.

6. 

TEST

button red LED and display warning symbols will flash during a 

test to show high voltage present at terminals.

7. Timer will count up from zero during test.

Voltage at terminals

Battery level

Warning
voltage at
terminals

Digital
display

Timer

Analogue
display

Warning
voltage at
terminals

Capacitance display

Time constant

Содержание MIT510/2

Страница 1: ...M MIT510 2 5kV Digital Insulation Tester USER MANUAL...

Страница 2: ...d items should be firmly shorted out with a shorting link after discharge until required for use This is to guard against any stored dielectric absorption charge subsequently being released thereby ra...

Страница 3: ...ndicate best practice Cleaning Disconnect the instrument and wipe it with a clean cloth slightly damped with soapy water or Isopropyl alcohol IPA CONTENTS 3 Safety warnings 2 Cleaning 3 Introduction 4...

Страница 4: ...harge the battery after each use A completely exhausted battery will take 14 hours to recharge INTRODUCTION POWER LEAD AND CHARGING 4 The MIT510 2 is a compact microprocessor controlled high voltage d...

Страница 5: ...t first will perform a self check during which Ini is displayed After Ini disappears the instrument is ready for use 3 Check voltage at terminals display to be sure the load is safe to energise 4 Set...

Страница 6: ...played briefly When the test has stopped the display continues to show the voltage present on the test leads Pressing either test voltage s or t button will then display the test voltage immediately b...

Страница 7: ...rminals marked and G These terminals are designed to accept only the test leads supplied Shutters across the terminals prevent accidental ingress of dirt and other objects Test lead plugs interlock wi...

Страница 8: ...display shows the last measurement made until the timer or voltage test settings are changed or the test start stop button is pressed Analogue display This simulates an analogue meter movement to give...

Страница 9: ...en the positive and negative terminals These leakages have a significant effect and can occur through the air itself If the guard lead is connected to ground then since the negative terminal is at the...

Страница 10: ...rt circuit charge current 3 mA 5 kV Capacitor charge time 3 seconds per F at 3mA to 5 kV Capacitor discharge time 120 ms per F to discharge from 5000 V to 50 V Capacitance measurement 500 V minimum te...

Страница 11: ...nA at all voltages Interference rejection 1 mA rms per 250 V test voltage up to a maximum of 2 mA Timer range Counts up to 99 minutes from start of test Test regimes Auto IR Lead set Three flexible si...

Страница 12: ...insulated small clips 8101 183 3 x 10 m with medium insulated clips 1000 441 3 x 15 m with medium insulated clips 1000 442 3 x 3 m with large insulated clips 6220 811 3 x 10 m with large insulated cl...

Страница 13: ...or your Megger products Returning your product to Megger UK and USA service centres 1 When an instrument requires recalibration or in the event of a repair being necessary a Returns Authorisation RA n...

Страница 14: ...2 Canada T 1 416 298 9688 Canada only T 1 416 298 6770 F 1 416 298 0848 E casales megger com Megger 501 Crystal Paradise Mall Off Veera Desai Road Andheri w Mumbai 400053 Maharashtra India T 91 22 267...

Отзывы: