Megger EVCC300 Скачать руководство пользователя страница 4

These safety warnings must be read and understood before the instrument is used. They must be observed 
during use. THE EQUIPMENT MUST BE USED ONLY BY SUITABLY TRAINED AND COMPETENT PERSONS. 
National Health and Safety Legislation requires users of this equipment or their employer to carry out valid 
risk assessment of all work so as to identify potential sources of danger and to mitigate risk.

 

If this equipment is modified or used in 

a manner other than specified by the 

manufacturer, the protection provided by the 

equipment may be impaired.

 

This equipment is not intrinsically safe and must 

not be used in hazardous atmospheres.

 

This equipment is for indoor and outdoor use  

up to 2,000m altitude. It must not be used 

in wet conditions or outside the specified 

temperature range.

 

Use only the adapters provided with  

the instrument.

 

If the equipment gets wet, turn off and 

disconnect, and wait for it to dry before  

turning back on. Clean equipment with a dry, 

clean cloth.

 

Inspect the equipment for damage before each 

use. The equipment must not be used if any part 

of it is damaged.

 

The touch-pad test must not be relied on 

to check protective earth integrity. It is an 

‘open-circuit’ test and will not indicate a high 

impedance earth connection.

 

The live phase indicators are an additional safety 

feature which may fail. Use independent means 

to verify whether circuits are energised. Safe 

working practice must be observed.

 

The PE (protective earth) pre-test must be carried 

out before any other test.

 

If the PE pre-test fail, there may be high voltage 

present within the charging station and on the 

output terminals and a risk of electric shock. 

Other tests must not be started until the fault is 

investigated and rectified.

 

If no voltage is present between the L & N of 

the terminals or between the L & N of the test 

connector when the instrument is connected to 

the charging point in charging mode, this may 

be because the instrument’s internal fuse  

has blown.

 

Disconnect from all other equipment before 

opening the fuse or battery compartments.

 

Replacement fuses must be of the correct type 

and rating. Failure to fit the correctly rated fuse 

may result in a safety hazard and may cause 

damage to the instrument in the event of  

an overload.

 

Use only non-rechargeable cells as specified in 

the instructions.

 

Replacement cells must be of the type specified 

in the instructions. Observe the correct polarity

 

No user serviceable parts are inside the 

equipment. Refer repairs to Megger approved 

service centres.

 

At the end of the equipment’s life dispose of it 

according to local regulations for recycling.  

Do not dispose of this equipment to landfill, 
sewage systems or by fire.

Test lead safety warnings: 

Test leads, including crocodile clips, must be in good 
condition, clean, dry and free of broken or cracked 
insulation. The lead set or its components must not be used 
if any part of it is damaged.
Overload categories for mains connections are rated as 
follows:

CAT IV

 - Measurement category IV: Equipment connected 

between the origin of the low-voltage mains supply and the 
distribution panel.

CAT III

 - Measurement category III: Equipment connected 

between the distribution panel and the electrical outlets.

CAT II

 - Measurement category II: Equipment connected 

between the electrical outlets and the user’s equipment.
Measurement equipment may be safely connected only to 
circuits at the marked rating or lower.

Safety symbols marked on the instrument

G

Refer to user instructions

F

HIGH VOLTAGE. Risk of electric shock

DOUBLE INSULATED. This instrument 
has double or reinforced insulation 
throughout.
Equipment complies with  
current EU directives 
Equipment complies with current UK 
legislation
N13117 Equipment complies with current  
“C tick” requirements
Do not dispose of to landfill, sewage 
systems or by fire

EN

Safety warnings

www.megger.com

EVCC300

4

Содержание EVCC300

Страница 1: ...Quick Start Guide EN DE FR ES NL For User Guide and other language versions please visit megger com support EVCC300 Electric Vehicle Charger Checker Mode 3...

Страница 2: ...ve Technical Support Latest Updates Visit megger com register DE Um Ihr Produkt zu registrieren besuchen Sie de megger com registrieren FR Pour enregistrer votre visite produit fr megger com registre...

Страница 3: ...1 2 3 4 5 6 7 8 www megger com EVCC300 3 Quick Start Guide...

Страница 4: ...when the instrument is connected to the charging point in charging mode this may be because the instrument s internal fuse has blown Disconnect from all other equipment before opening the fuse or bat...

Страница 5: ...e Spannung zwischen L und N der Anschl sse oder zwischen L und N des Pr fsteckverbinders anliegt wenn das Ger t im Lademodus an die Ladestation angeschlossen ist ist m glicherweise die interne Sicheru...

Страница 6: ...sion n est pr sente entre les L et N des bornes ou entre les L et N du connecteur de test lorsque l instrument est connect la station de charge en mode charge cela peut tre d au fait que le fusible in...

Страница 7: ...ndo el instrumento est conectado al punto de carga en modo de carga puede deberse a que el fusible interno del instrumento se haya fundido Descon ctelo del resto de equipos antes de abrir el compartim...

Страница 8: ...Als er geen spanning aanwezig is tussen de L N van de klemmen of tussen de L N van de testconnector wanneer het instrument is aangesloten op het laadpunt en in laadmodus is kan dit komen doordat de in...