1 SAFETy  

S

afety  

1.1 Safety instructions

For your own safety and to get the maximum benefit 
from your instrument, please ensure that you read 
and understand the following safety instructions and 
warnings before using the instrument.

Read and comply with the following 
instructions. 
Always comply with local safety 
regulations.

Important

Warning

Connecting – before test

1. 

 

Before measuring resistance in circuit breakers 
or disconnecting switches (isolators), always 
check to see that the object being tested is 
closed and grounded at least on one side.

2. 

 

Do not connect the instrument to inductive 
loads if not necessary. This can cause high volt-
ages when removing the current clamps and 
possibly damage MOM2.

3. 

 

Always connect the protective ground on 
MOM2 before making any other connections.

4. 

 

Always connect the test cables to MOM2 be-
fore connecting them to the test object.

5. 

 

Never connect MOM2 to live circuits.

During test

1. 

 

The rising current waveforms produced by the 
instrument may induce enough current into 
the secondary of a current transformer (CT) 
circuit to actuate a protective relay.  
If there is a CT in the current circuit, the pro-
tective relay equipment that is connected to it 
must be blocked to prevent actuation.  
After completing the measurements, you can 
follow the normal procedures that are used to 
demagnetize current transformer cores after 
DC has passed through their current trans-
former.

2. 

 

Never open a circuit breaker while MOM2 is 
connected to it.

3. 

 

Connection points for current cables can be-
come hot during current generation.

4. 

 

High current on output terminals.

Disconnecting – after test

1. 

 

First, disconnect all test cables from the test 
object and then disconnect them from MOM2.
Last, disconnect the protective ground from 
MOM2.

Important

1. 

 

The instrument is intended for use in industrial 
environment. It generates, uses and can radi-
ate radio frequency energy and, if not installed 
and used in accordance with these instructions 
it may cause interference to other devices 
in the vicinity. If this equipment does cause 
interference with other devices, which can be 
determined by turning the equipment off and 
on, the user is encouraged to try to correct the 
interference by one or more of the following 
measures:

 

Reorient or relocate the receiving device.

 

Increase the separation between the equipments.

 

Consult the manufacturer or field service 
technician for help.

2. 

 

Never leave the MOM2 unattended while it is 
turned on.

3. 

 

Do not use any accessories that are not in-
tended for use together with the instrument.

4. 

 

It is not possible to use the MOM2 for testing 
during battery charging.

5. 

 

Use a damp cloth for cleaning. Do not use 
liquid cleaners or aerosol cleaners.

6. 

 

Do not attempt to service the instrument your-
self. If you attempt to service the instrument 
yourself the warranty is no longer valid. Refer 
all servicing to Megger authorized personnel.

7. 

 

If you need to return the instrument, please 
use either the original crate or one of equiva-
lent strength.

www.

.com

[email protected]

1.800.561.8187

Содержание BD-59090

Страница 1: ...User guide MOM2 MOM2 Win Micro ohmmeter Art No ZP BD03E Doc BD0333JE V09a 2020 www com information itm com 1 800 561 8187...

Страница 2: ...commitment on the part of Megger Sweden AB Any attached hardware schematics and technical descriptions or software listings that disclose source code are for informational purposes only Reproduction...

Страница 3: ...choose measurement time 22 To choose I Imin or I Imax 22 Working at low temperatures 23 Kelvin Clamp Probe practice 23 Save test results 23 Hold present test result 23 Delete present test result 23 R...

Страница 4: ...35 Manual connecting 35 7 5 Read the measurement log 37 Export data to file 38 Delete all data on the instrument 38 7 6 User settings 39 Read existing settings 39 Program User positions 39 7 7 Calibr...

Страница 5: ...ans former 2 Never open a circuit breaker while MOM2 is connected to it 3 Connection points for current cables can be come hot during current generation 4 High current on output terminals Disconnectin...

Страница 6: ...ize your lo cal WEEE collection facilities in the disposal of this product and otherwise observe all applicable requirements Equipment complies with current EU directives Information duty regarding su...

Страница 7: ...that they can be remedied long before trouble starts Checking contact resistance at regular intervals provides a clear indication of the state of your system Unpack system Unpack the unit and check fo...

Страница 8: ...2 it is possible to make measurements according to the DualGround method The most im portant advantage is improved safety but the method is also easier and saves time The number of tasks is reduced wh...

Страница 9: ...OM2 overview 3 MOM2 overview 3 1 The instrument 1 2 4 5 6 7 8 3 9 10 11 Top view 12 13 14 Bottom view 1 Current output terminal 2 Current output terminal 3 Protective conductor terminal www com inform...

Страница 10: ...the po sitions I Imin I Imax or USER measure ment is performed by pressing the button 7 Stand by Wake up Press shortly to toggle Clear log Press and hold for 5 s 8 Function selector OFF I I min 0 1 s...

Страница 11: ...ables with Kelvin clamps Transport case Charger Rubber holster Carrying strap Belt clip MOM2 Win GA 90000 Test cables with Kelvin probes incl in BD 59090 GA 90001 Test cables with Kelvin clamps incl i...

Страница 12: ...ith Kelvin clamp 5 m 16 ft black 25 mm2 GA 00374 Test cable with Kelvin clamp 10m 33ft black 16 mm2 This length in combination with the cable area 16 mm2 results in a reduction of maximum current GA 0...

Страница 13: ...n use Note The MOM2 will go to stand by mode after about 10 minutes of inactivity To wake up press Stand by Wake up CLR LOG button 4 2 Test positions I I min Minimum current is set in position SET I m...

Страница 14: ...rches for MOM2 and after a while the MOM2 device is found 6 Select the MOM2 item and press Next After this a menu appears that asks for the passcode 7 Enter code 0000 and press Next The installation n...

Страница 15: ...r non Month dd Day HH Hour nIn Minute Date and time 1 Select SET CLC 2 Press and hold OK key until digits start to blink under the yy letters 3 Set year using the keys 4 Press OK key 5 Press the key t...

Страница 16: ...imum cur rent showing 037 A 4 6 Data logger LOG The data memory can store totally 104 measurements and this capacity is shared by the two log modes SET LOG Display abbreviations description SEL Select...

Страница 17: ...value exceeds the set limit it will result in a notification on the dis play and by an audio signal SET P F Display abbreviations SEL Select oFF OFF Set up 1 Select SET P F Present setting is display...

Страница 18: ...ent action The sound is emitted from a built in buzzer and from the Bluetooth headset optional The audio signals vary in frequency Low High and composition Audio signals Description The MOM2 is chargi...

Страница 19: ...or other fault Check batteries and charger cables Replacing the batteries 1 Loosen the two screws that holds the battery plate at the back of MOM2 see figure below It is recommended to use the same t...

Страница 20: ...Functions and set up Note If the batteries are fully discharged it will be impossible to charge them in the MOM2 However a separate battery charger may be able to charge the batteries www com informa...

Страница 21: ...cator In this case the Pass Fail is set to 100 7 Padlock symbol The lock symbol is shown when the capacitor is charged prior to a test and when you lock a test result To choose measurement time In an...

Страница 22: ...alue is stored and only until the performance of a following measurement which overwrites the previous one Hold present test result When the LOG function is activated the measurement result is shown o...

Страница 23: ...citor by a repeated sound and on the display shows alternating CAP and CHG and the lock symbol Charging 6 The MOM2 is ready for a measurement when the lock symbol disappears Ready for test 7 Press the...

Страница 24: ...the padlock symbol Charging 6 When the lock symbol disappears the MOM2 is ready for a measurement Ready for test 7 Press the TEST button on MOM2 or Trigger on the probe A continuous audio signal tells...

Страница 25: ...sistance value is below the P F limit The result will be shown on the display with big digits The small digits toggle between the P F limit and the max min current values Here P F limit was set to 150...

Страница 26: ...ull Running numbers 1999 The display before first measurement The display after measurements By using the and keys you can scroll be tween the saved test results Note You can only scroll through the m...

Страница 27: ...label e g 1A1 the lock sign is shown Note To continue to measure you need to either delete the latest measurement or scroll to a blank label By using the and keys you can toggle be tween the saved te...

Страница 28: ...plete there will be a pass or a fail signal A If the resistance value is below the P F limit and the current value is over the set min current limit the result will be shown on the display with big di...

Страница 29: ...0 1 second and one with 3 seconds setting If the values are equal then there is no current transformer in the loop If you get different readings it might be a need for a workaround 1 If possible incr...

Страница 30: ...BD0333JE ZP BD03E MOM2 31 6 Application examples www com information itm com 1 800 561 8187...

Страница 31: ...mance if you only want to know if the test object pass a preset value and you do not need to store the test results 1 Select LOG function OFF and set P F value see section 4 6 and 4 7 2 Attach the tes...

Страница 32: ...connect ed closed and grounded on both sides 2 Connect the MOM2 to ground 3 Attach an extra ground cable not included with at least 95 mm2 cross section area to one side of the CB 4 Connect the 0 5 m...

Страница 33: ...talled see the installation instructions supplied with the dongle Setup 1 Insert the USB stick with the MOM2 Win sw Select and run the file Setup exe to install the program The program will be install...

Страница 34: ...the MOM2 instrument At program startup the SW will try to connect to MOM2 using the same COM port that the last suc cessful connection used If there have been no previ ous MOM2 connections from this...

Страница 35: ...window searching Figure 7 4 The Connection settings window connection established Refresh button Provided that the MOM2 and the PC are connected to each other the MOM2 date and time and the PC date an...

Страница 36: ...7 5 Data dumping dialog 2 Click on the Retrieve all data button to download all measurements stored in the instrument A window will pop up showing the progress of the download At any time the data dum...

Страница 37: ...t ed values suited for import to e g Microsoft Excel Note The value separator is dependent of the re gional setting in Windows a semicolon when comma is used for decimal separator and comma otherwise...

Страница 38: ...No 1 3 2 Click the Read from instrument button to see the current settings on the instrument All three user settings will be read not only the one selected in the combo box The val ues for minimum cu...

Страница 39: ...MOM2 will then be propagated to the U measured text field New calibration factors will automatically be calculated 5 Click the Verify button The voltage measured with the new calibration factor will...

Страница 40: ...have been measured and the result is satis factory you can save it to the MOM2 8 Click the Save to instrument button 9 If the result of the tests is not satisfying or you want to start over click the...

Страница 41: ...ns Instrument excl binding posts 217 x 104 x 72 mm 8 5 x 4 1 x 2 8 in Carrying case 395 x 300 x 190 mm 15 6 x 11 8 x 7 5 in Weight 1 0 kg 2 2 lbs instrument only 5 0 kg 11 lbs with accessories and car...

Страница 42: ...BD0333JE ZP BD03E MOM2 43 www com information itm com 1 800 561 8187...

Страница 43: ...ccessories 12 Input for sensing voltage 11 Input for sensing voltage 11 K Kelvin Clamp Probe practice 23 Kelvin test 9 Keys 11 L LCD display 22 LOG 17 low temperatures 23 M Measurement on using Kelvin...

Страница 44: ...Test a CB using DualGround 33 TEST button 11 Testing on circuit breakers having a current transformer in the loop 30 Test positions 14 To choose I Imin or I Imax 22 To choose measurement time 22 Trai...

Страница 45: ...esting Equipment Low Resistance Ohmmeters Motor Phase Rotation Test Equipment Multimeters Oil Test Equipment Portable Appliance Tool Testers Power Quality Instruments Recloser Test Equipment Relay Tes...

Отзывы: