22
MOM2
ZP-BD03E
BD0333JE
5 OPERATING INSTRUCTIONS
5
O
perating instructions
5.1 General instructions
Important regarding all testing
Read and comply with the
safety instructions.
Always comply with local
safety regulations.
Important
Power supply
Prepare testing by charging the batteries se section
4.10 Battery power supply.
Note
The MOM2 cannot be used for testing during
battery charging.
LCD display
The display can be backlighted by pressing the key .
It is switched off automatically after 20 seconds.
1
4
2
3
1.
Analogue arc
Indicates level of the capacitor charge
2.
Measurement label
In this case the instrument is set in Running numbers
mode (
SET / LOG
)
3.
Measurement result
4.
Battery charge indicator
5
6
7
5.
Warning
See section 5.8 Troubleshooting
6.
Pass/Fail indicator
In this case the Pass/Fail is set to 100 μΩ
7.
Padlock symbol
The lock symbol is shown when the capacitor is
charged prior to a test and when you lock a test
result.
To choose measurement time
In an environment without electrical interference it is
wise to choose the shortest measurement time, which
means that you can get the largest number of meas-
urements on a single battery charge.
Note
The shortest measurement time (0.1 s) is not
suitable in environments with a frequency of
16 2 / 3 Hz.
Tip:
Start making three tests with the shortest
measurement time to figure out if the results
vary. If they do not differ significantly - use 0.1
s for the tests.
To choose I > I min or I = I max
If you want maximum current for the test, choose
I = I max
. The capacitor will be charged to its maxi-
mum and requires much energy from the batteries.
If lower current is sufficient for the measurement,
it is advisable to use the
I > I min
position. In the
www.
.com
1.800.561.8187