SAFETY MANUAL 

Electrical safety 

 

 

PPM0732  pulse  generator  module  is  high  voltage  equipment.  Please  be 
very careful and operate by qualified personnel only. 

 

There  is  a  risk  of  electric  shock,  strong  electromagnetic  interference, 
damage of the generator, or other electronic equipment in case of improper 
use. 

 

It  is  strongly  prohibited  to  switch  on  the  generator  without  an  output 
coaxial cable. We recommend using at least 50 centimeters length coaxial 
cable  connected  between  the  generator  and  the  load  (antenna  or  first 
attenuator) to prevent permanent damage to the generator. There is a risk of 
electrical  arcing  on  the  open  HV  coaxial  connector  and  damage  to  the 
output circuit of the generator.  

 

When adding or removing the generator to or from the system, ensure that 
the  power  supply  is  unplugged  (in  OFF  state).  Please  apply  power  supply 
only after connecting output and input coaxial cables.  

 

Please  provide  sufficient  free  space  and  allow  free  airflow  around  the 
generator  for  good  cooling  in  case  of  long  time  operation  at  a  high 
repetition rate.  

 

Operation safety 

 

 

Please read this manual before installing and using the generator. 

 

Before  using  the  product, make  sure  that all the  cables are applicable  and 
not damaged. High voltage connectors should be clean and dry, free from 
dust, dirt, and any obstacles. 

 

To  avoid  short  circuits,  keep  metal  parts  like  clips,  screws,  and  staples 
away from the generator. 

 

The  generator  is  designed  for  operation  in  normal  laboratory  conditions. 
Avoid  dust,  humidity,  and  temperature  extremes.  Do  not  place  the 
generator in any place where it may become wet.  

 

Place the generator on a stable surface. 

 

If  you  encounter  any  technical  problem  with the  generator,  please  contact 
Megaimpulse Ltd. Do not try to repair the generator by yourself. 

 

MEGAIMPULSE LTD.                                                                                                2

 

Содержание PPM0732

Страница 1: ...PICOSECOND PULSE GENERATOR MODULE PPM0732 USER MANUAL 2022 Megaimpulse Ltd...

Страница 2: ...ERROR IN THIS MANUAL OR PRODUCT SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE FURNISHED FOR INFORMATION ONLY AND ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE AND SHOULD NOT BE CONST...

Страница 3: ...ew of picosecond pulse generator 3 Description of the generator operation 4 Technical specification 7 Top front and rear panels view 8 Bottom view 9 Putting the generator into operation 10 Triggering...

Страница 4: ...plugged in OFF state Please apply power supply only after connecting output and input coaxial cables Please provide sufficient free space and allow free airflow around the generator for good cooling i...

Страница 5: ...0 6A DC 160V 0 3A Semirigid coaxial cable assembly N connector SM141 cable open for the output pulses feeding and connection to the load by soldering or optional connector Coaxial cable assembly SMA c...

Страница 6: ...abels and contact pins description Improper connection may damage the generator permanently The ground wires of the power supply cable are marked by black color Low voltage and high voltage supply wir...

Страница 7: ...triggered by the leading edge of the external triggering pulse There is no internal triggering mode Acceptable triggering pulse amplitude is 3 5V 5V at 50 Ohm Low triggering pulse amplitude leads to...

Страница 8: ...and stay within 168 ns 175 ns because the phase capture window tw is 7 ns only The capture window tw is narrow but it is enough to compensate for the temperature drift and aging of the components Ther...

Страница 9: ...ns Triggering External only Input triggering pulse connector SMA Triggering pulse parameters 5V amplitude on 50 Ohm width 170 ns nominal 168 ns 175 ns acceptable for PLL 10 ns 1000 ns suitable for tr...

Страница 10: ...green high voltage 160V DC power supply is applied SYNC IN orange triggering of the generator OVERHEAT red too high temperature OVERLOAD red too high repetition rate 2 Input triggering SMA connector...

Страница 11: ...nt is required if the pulse position is correct at some repetition rate for example at 1kHz but shifted up to 1 ns at another repetition rate for example at 5 kHz INT_DELAY adjusts the internal delay...

Страница 12: ...ower supplies according to the recommended low voltage and high voltage levels before connecting to the generator Check the power supply cable and connect it correctly The ground wires are marked by b...

Страница 13: ...nerator is designed for the long time operation at the max repetition rate But it can be overheated in the case of unmatched load and high ambient temperature Please provide free airflow around the ge...

Страница 14: ...Fig 5 Nominal triggering pulse amplitude is 5V on 50 Ohm pulse duration should be within 10 ns 1000 ns rise and fall time should be 1 ns or less Longer rise fall time may result in increasing of the o...

Страница 15: ...RRANTY Please see your sales agreement to determine the warranty period and warranty terms The generator has warranty seals Removing of the warranty seals terminates the warranty PPM0732 User Manual 1...

Отзывы: