background image

BOTTOM VIEW 

 

 

 
 

There are five holes on the bottom which give access to the trimmers for 

the fine-tuning of PPM0732 operation. The holes are closed by the hexagon socket 
set  screws.  Please  use  the  hex  screwdriver  to  remove  them.  The  generator  has 
been already adjusted at the factory. Therefore, normally the additional adjustment 
is not required in the End User laboratory. Please consult with Megaimpulse Ltd. 
before adjusting the trimmers. 
 
FEEDBACK  –  corrects  the  possible  skew  of  the  output  pulse  relative  to  the 
trailing edge of the triggering pulse at different repetition rates. The adjustment is 
required  if  the  pulse  position  is  correct  at  some  repetition  rate  (for  example  at 
1kHz) but shifted up to 1 ns at another repetition rate (for example at 5 kHz). 

INT_DELAY – adjusts the internal delay of the generator which allows to shift of 
the  phase  capture  window  and  make  it the  same  for all the generators  within  the 
array. 

SET_TEMP – sets the temperature which the cooling system will keep stable by 
changing the fans rotating speed. 

AMPLITUDE – adjusts the amplitude of the output pulse. Please be careful with 
this trimmer, too high set amplitude may result in permanent damage to the output 
HV components.  

WAVEFORM  –  adjusts  the  output  pulse  waveform  which  helps  to  make  output 
pulse more narrow and sharp, as well as adjusts the prepulse amplitude and pulse 
width. 

PPM0732 User Manual                                                                                             9

 

Содержание PPM0732

Страница 1: ...PICOSECOND PULSE GENERATOR MODULE PPM0732 USER MANUAL 2022 Megaimpulse Ltd...

Страница 2: ...ERROR IN THIS MANUAL OR PRODUCT SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE FURNISHED FOR INFORMATION ONLY AND ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE AND SHOULD NOT BE CONST...

Страница 3: ...ew of picosecond pulse generator 3 Description of the generator operation 4 Technical specification 7 Top front and rear panels view 8 Bottom view 9 Putting the generator into operation 10 Triggering...

Страница 4: ...plugged in OFF state Please apply power supply only after connecting output and input coaxial cables Please provide sufficient free space and allow free airflow around the generator for good cooling i...

Страница 5: ...0 6A DC 160V 0 3A Semirigid coaxial cable assembly N connector SM141 cable open for the output pulses feeding and connection to the load by soldering or optional connector Coaxial cable assembly SMA c...

Страница 6: ...abels and contact pins description Improper connection may damage the generator permanently The ground wires of the power supply cable are marked by black color Low voltage and high voltage supply wir...

Страница 7: ...triggered by the leading edge of the external triggering pulse There is no internal triggering mode Acceptable triggering pulse amplitude is 3 5V 5V at 50 Ohm Low triggering pulse amplitude leads to...

Страница 8: ...and stay within 168 ns 175 ns because the phase capture window tw is 7 ns only The capture window tw is narrow but it is enough to compensate for the temperature drift and aging of the components Ther...

Страница 9: ...ns Triggering External only Input triggering pulse connector SMA Triggering pulse parameters 5V amplitude on 50 Ohm width 170 ns nominal 168 ns 175 ns acceptable for PLL 10 ns 1000 ns suitable for tr...

Страница 10: ...green high voltage 160V DC power supply is applied SYNC IN orange triggering of the generator OVERHEAT red too high temperature OVERLOAD red too high repetition rate 2 Input triggering SMA connector...

Страница 11: ...nt is required if the pulse position is correct at some repetition rate for example at 1kHz but shifted up to 1 ns at another repetition rate for example at 5 kHz INT_DELAY adjusts the internal delay...

Страница 12: ...ower supplies according to the recommended low voltage and high voltage levels before connecting to the generator Check the power supply cable and connect it correctly The ground wires are marked by b...

Страница 13: ...nerator is designed for the long time operation at the max repetition rate But it can be overheated in the case of unmatched load and high ambient temperature Please provide free airflow around the ge...

Страница 14: ...Fig 5 Nominal triggering pulse amplitude is 5V on 50 Ohm pulse duration should be within 10 ns 1000 ns rise and fall time should be 1 ns or less Longer rise fall time may result in increasing of the o...

Страница 15: ...RRANTY Please see your sales agreement to determine the warranty period and warranty terms The generator has warranty seals Removing of the warranty seals terminates the warranty PPM0732 User Manual 1...