background image

Cleaning and maintenance 

Installation Maintenance: 

The operator has to make sure that the unit is operating safely and has the installa-

tions and electronics checked by an expert every 2 years. 

 

The following points have to be considered during the inspection: 

1)  All screws used for installing the device or part of the device have to be tightly connected and must not be corroded. 

2)  There must not be any deformations on the housing, fixation and installation spots (ceiling, suspension, trussing). 

3)  Mechanically moved parts like axles and other must not show any traces of wearing and must not rotate with unbal-

ances. 

4)  The electronic power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments.  

Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any 

safety problems have to be removed. 

Disconnect from mains before starting maintenance operation! 

 

 

 

    Caution Danger to life!

 

 

 

 

 

We recommend a frequent cleaning of the device.  Please use a moist, lint free cloth.  Never use alcohol or solvents! 

1)  The objective lens will require periodic cleaning on usage and environment.  Environment with foggers will require 

more periodic cleaning as fog fluid tends to build up residues, reducing the light output. 

2)  The cooling-fans should be cleaned monthly.  DO NOT blow high pressure air into fans as incorrect rotation can 

damage the fans operation. 

3)  The gobos, dichroic color filters and internal lenses may be cleaned with soft brush using soapy water. 

4)  The interior of the fixture should be cleaned using a vacuum. 

5)  We recommend proper lubrication of the motor wheel.  The quantity of the oil must not be excessive in order to avoid 

oil run outs when motor wheel rotates 

Note: 

There is no serviceable parts inside the device except for the fuse.  Maintenance and service operations 

are to be carried out by authorized dealers. 

Replacing the fuse:  

Only replace the fuse with the same type and rating. 

Replacing the power cable:  

If the power cable of this device becomes damaged, it has to be replaced by author-

ized dealers only 

Should you have further questions , please contact your dealer. 

11 

Parts List 

1160-PS 

Power Supply 

1160-MPCB 

Main PCB 

1160-LED

Osram LED 60W RGBW 

1160-LEDMOD 

LED on PCB 

1160-RC4 

4 Unit Road Case 

1160-FAN 

Fan 

1160-DMX5 

5pin DMX Panel Mount Connector 

1160-DMX3 

3pin DMX Panel Mount Connector 

1160-TSEN 

Tilt Motor Sensor 

1160-MOT 

Motor 

1160-LEN 

Lens 

1160-PSEN 

Pan Motor Sensor 

1160-QR 

Quick Release Clamp Mount 

Содержание AXIS CYCLOPS

Страница 1: ...MANUAL Table of Contents Safety Information 3 Specifications 4 Main Power Connection 5 DMX 512 Connection 6 Rigging the Fixture 6 Main Control Menu 7 DMX Profile 10 Cleaning Maintenance 11 Parts List...

Страница 2: ......

Страница 3: ...ly secured away from unit movement 6 Maximum surface operating temperature 104 Protection Against Fire 1 Disconnect power before lamp replacement or servicing 2 For connection to main power supply pro...

Страница 4: ...and 5 pin XLR connectors Power Connectors Power Con type in and out Thermal Maximum ambient temperature 100 F Maximum surface temperature 130 F Fastening System Single Quick Release Clamp Mounts Lens...

Страница 5: ...only with the specified type and rating The occupation of the connection cable is as follows This device is equipped with a auto switching power supply that will allow you to work from 100V 240V 50 60...

Страница 6: ...decoration material 4 Use high quality installation equipment to hang unit When rigging a unit it is very important that you follow common safety procedures Rigging requires extensive experi ence inc...

Страница 7: ...Mode 5 Manual Control 6 Slave Mode 1 Pan 2 Tilt 3 Dimmer 4 Red Intensity 5 Green Intensity 6 Blue Intensity 7 White Intensity 8 Shutter Strobe 9 Control 1 Pan 2 Pan Fine 3 Tilt 4 Tilt Fine 5 Pan Tilt...

Страница 8: ...e 12 P T Fedback Press the knob to select DMX Clear Select yes if you would like to bring DMX attributes to zero if DMX signal is lost Select no if you would like DMX attributes to be kept to the last...

Страница 9: ...s to reset the fixture s motor and dimmer settings Reset 13 Display Rotate 14 Back Light 15 Version 16 Factory Set 17 Reset 18 Calibration Press the knob to find out what version of software is being...

Страница 10: ...nel Function Description Value Init Value 1 Pan Pan Course 0 255 128 2 Pan Fine Pan Fine 0 255 128 3 Tilt Tilt Course 0 255 128 4 Tilt Fine Tilt Fine 0 255 128 5 Pan Tilt Speed Pan Speed fast to slow...

Страница 11: ...t Environment with foggers will require more periodic cleaning as fog fluid tends to build up residues reducing the light output 2 The cooling fans should be cleaned monthly DO NOT blow high pressure...

Страница 12: ...id by MSI via the most economical means of shipment Repair or replacement as provided for under this warranty is the exclusive remedy of the consumer MEGA SYSTEMS INC makes no warranties express or im...

Отзывы: