If the voltage is well below the output voltage of the DC Controller then the
bar should be returned to Meech for service and/or repair.
If no meter and probe is available, then a fast and simple test can be
undertaken by shorting a pin of the bar to earth.
Attach a short length of insulated wire to a known earth.
Holding the wire insulation, approach any of the bar emitter pins with
the bare end of the wire.
As the pin is approached, a small faint spark should jump from the pin
to the wire.
As the spark is drawn a slight buzzing sound will also be heard. This
indicates that the bar is functioning correctly.
If there is more than one bar to test, disconnect the first item and repeat the
above steps with subsequent bars.