11
WARNING
Meech Pulsed DC Controllers require a grounded 24V DC supply. The 0V line
must
be connected to ground. Failure to do so, will result in damage to the
ioniser or the 24V supply and will void the warranty.
The shockless emitter pins produce ions of positive and negative polarity.
These, because of the product’s unique design, propel themselves away from
the emitter points towards the target area.
The maximum output voltageis 5.5kV to respect the ATEX certification of the
924EX bar.
Optimum static elimination can be achieved by adjustment of the “Rate”
(frequency of pulsing) and the “Balance” (proportion of positive to negative
ions generated) on the Controller.
If the bar is positioned a long distance from the target area the “Rate” should
be set to the lowest setting. If the bar is positioned close to the target area
the “Rate” should be set towards its maximum.
WARNING
Meech Pulsed DC Controllers require a grounded 24V DC supply. The 0V line
must
be connected to ground. Failure to do so, will result in damage to the
ioniser or the 24V supply and will void the warranty.