9
Installation
The Model 924EX Bar should be located in the most convenient position so
that the pins of the Bar are directed towards the target area. The bar should
be positioned to give an unrestricted path for the ions to travel to the target
area.
The Meech Model 924EX must be connected to a Pulsed DC Controller, which
must be located outside of any EX zoned area.
POWER, INPUT AND OUTPUT (I/O) WIRING MUST BE IN ACCORDANCE WITH
CLASS 1, DIVISION 1 WIRING METHODS ARTICLE 501.10(b) OF THE NATIONAL
ELECTRICAL CODE , NFPA 70.
A) THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS 1, DIVISION 1, II 2G IIC T4
GB, OR NON HAZARDOUS LOCATIONS ONLY
B) WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY
IMPAIR SUITABILITY FOR CLASS 1, DIVISION 1
C) WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT
UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO
BE NON-HAZARDOUS.
The 924EX connects to the Pulsed DC Controller by plugging the male plugs,
found at the end of the bar cabling, directly into the high voltage sockets of
the controller. The plugs and sockets are marked with “+” positive and “-”
negative indicators for correct connection to the power supply.