6
Installation
The 915EX Bar can be placed between 25mm and 150 mm from the surface to be
neutralised. It is important to ensure that the surface to be neutralised has free air on
both sides and that earthed metal objects are, where possible, at least 20 mm away
from the bar. These precautions will maximise the unit’s ionisation capability.
Good results can be achieved at distances up to 150mm but as the distance from the
object increases, the speed of charge neutralisation will decrease.
A typical installation distance is 50mm from the target surface. This gives excellent
performance at high web or product speeds, whilst avoiding possible damage from
web breaks or product mis-feeds. Very fast webs may require the bar to be as close
as 25mm to the web.
Correct positioning of the bar(s) is vital to efficient operation. The following diagrams
show the correct installation procedures:
1. The optimal distance from material to be neutralised.