4. Having checked the power unit, reconnect one Model 915EX ionising bar.
5. Using a high voltage probe and meter measure the voltage on the pins of the
ionising bar. This voltage should be approximately 6.5 kV.
CAUTION:
This test must only be carried out when the installation area is non-hazardous. This
may require the bar to be removed from its normal installation position.
6. If the voltage is below 4.0 kV then the bar should be returned to Meech for service
and/or repair.
7. If there is more than one bar to test, disconnect the first item and repeat the above