Model 915EX

Shockless AC Bar

Operating 

Manual

Содержание 915EX

Страница 1: ...Model 915EX Shockless AC Bar Operating Manual...

Страница 2: ......

Страница 3: ...Maintenance 10 Fault Finding 11 Repairs and Warranty 14 CE Approval 15 Health and Safety 15 Products shown in this document may be covered by one or more patents patents applied for and or registered...

Страница 4: ......

Страница 5: ...tic neutralisation performance This enables the bar to eliminate very high static charges on high speed webs and at longer ranges than has previously been possible Certification EC type examination ce...

Страница 6: ...The power supply shall be protected by a fuse capable of withstanding a prospective short circuit current of 4000A 3 The user must determine in consultation with Meech the suitability of the apparatu...

Страница 7: ...y coupled electrodes are energised by the AC voltage from the Power Unit The electrodes emit this energy corona discharge in the form of a field of ionised air This ionised air supplies ions of both p...

Страница 8: ...t distances up to 150mm but as the distance from the object increases the speed of charge neutralisation will decrease A typical installation distance is 50mm from the target surface This gives excell...

Страница 9: ...ice to provide a secondary grounding through the fixing points where practical The HT cable and armoured conduit require connection to a Meech model 904 power unit Please consult the 904 instruction m...

Страница 10: ...will distort the corona and reduce its efficiency 3 If bars are needed on both sides of the material they should be staggered 4 The bars must be earthed for correct operation If in any doubt run an ea...

Страница 11: ...effective length Cable 5 metres shielded in flexible conduit longer lengths can ordered Weight Approx 1 100gms per 1000mm length Cross section 18mm x 42mm inc of end caps Construction Anodised alumini...

Страница 12: ...lass 100 area cleaning may only be required on a monthly basis Before cleaning ensure that the equipment is switched off Emitter pins can be cleaned very effectively with a brush A dry toothbrush is i...

Страница 13: ...d such an event occur disconnect immediately and return equipment to the manufacturer for water damage assessment The Model 915EX ionising bar forms part of a system comprising the bar itself and a Mo...

Страница 14: ...12 2 Disconnect all ionising bars from the power unit 3 Follow the test procedure for the Model 904 Power Unit This can be found in the instruction manual of the Model 904...

Страница 15: ...ately 6 5 kV CAUTION This test must only be carried out when the installation area is non hazardous This may require the bar to be removed from its normal installation position 6 If the voltage is bel...

Страница 16: ...and must be shipped prepaid For prompt service ship the unit to the factory with the return authorisation number shown clearly on the label Be sure it is well packed in a sturdy carton with shock abso...

Страница 17: ...Conformity for this product exists in respect of the Low Voltage Directive 72 23 EEC LVD Electromagnetic Compatibility Directive 89 336 EEC EMCD Health and Safety Emission of Ozone Considerably below...

Страница 18: ...16...

Страница 19: ......

Страница 20: ...232 4210 Fax 1 330 564 2005 email info meech com Meech Shavotech 29 2 Kharadi Off Pune Nagar Road On Old Kharadi Mundhwa Road Pune 411014 Maharashtra India Tel 91 0 703 093 8211 91 0 741 000 4817 Fax...