7.1 Maintenance

7.2 Storage

7.3 Disposal

●  

Please often clean the device

●  

Use a soft, dry cloth to clean the surface of this device when it is dirty.

●  

Use an alcohol swab or cotton tissue moistened with alcohol (70% Isopropyl) to 

     clean the housing when it is very dirty and then use a dry cloth.

●  

Never use abrasive cleaning agents, thinners or benzene or other cleaning liquids.

●  

Take care not to scratch the surface of the sensor lens and LCD display.

●  

Clean the upper arm cuff with a damp cloth and mild detergent.

       

Do not wash the upper arm cuff using washer or dish-washing machine.

●  

The device requires no calibration.

●  

The device is not repairable and contains no user serviceable parts.

●  

No modification of this device is allowed.

●  

Please routine check the device. If you find the cuff is damaged, or LCD display 

     incomplete etc. please contact the customer service appointed by Med-link.

●  

We recommend this device is tested for accuracy every one year or after mechanical 

     impact (e.g.     being dropped). Please contact Med-link to arrange the test.

●  

Manufacturer will provide circuit diagrams, component part lists, descriptions, 

     calibration   instructions to assist to SERVICE PERSONNEL in parts repair.

●  

Do not use the device during maintenance.

       

Ensure no liquid enters the interior of the device. 

●  

Do not wet the upper arm cuff.

●  

Protect the device from:

    ‐

Water and moisture

    ‐

Extreme temperature (heat and cold)

    ‐

contamination and dust

    ‐

direct sunlight

    ‐

impact and dropping

●  

Remove the batteries if the device is not going to be used for long time (over 3 months).

Do not dispose of electrical appliances as unsorted municipal waste, use separate 

collection facilities. Contact your local government for information regarding the collection 

systems available. If electrical appliances are disposed of in landfills or dumps, 

hazardous substances can leak into the groundwater and get into the food chain, 

damaging your health and well-being.

7. Maintenance and Storage

9

The below table explains the error code that may display on the LCD:

The below table explains the error code that may display on the LCD:

No adequate pressure in the 

cuff (the inflation is less than 

30mmHg in 12 seconds)

1) Check that the cuff is correctly wrapped. (Please 

refer to 4.2)

2) The cuff leaks. Please contact Med-link.

Be quiet and repeat the measurement. (Please 

refer to 4.1)

Repeat the measurement

The cuff is too loose. Re-position the cuff and 

repeat the measurement. (Please refer to 4.2)

Error signal (movement, 

talking or

in a electromagnetic field) 

Pulse signal is too weak.

Repeat the measurement.

Abnormal result

Cuff pressure is too high (over 

295mmHg for 20ms)

5.Error Indication

Error code

Description

Remedy

How to correct

Abnormal situation

“Er U”

“Er H”

“Er 1”

“Er 2”

“Er 3”

If above abnormal situation are still persists or you have any further 

    questions please call Med-link customer service at 

400-058-0755

.

8

6.Troubleshooting

No display after batteries 

installation and power on.

(1) Check batteries’ polarity.

(2) If still cannot power on, reinstall or replace the batteries.

(1) Cuff is too loose; confirm the cuff is wrapped correctly.

(1) Blood pressure value is varied during the day which also 

     will affect by the human emotional and physical condition.

(2) Record the variance and consult your doctor.

(1) Cuff or bladder leakage, please contact Med-link.

(2) Confirm the cuff is wrapped up correctly (Refer to 4.2), 

     repeat the measurement.

(1) Confirm the cuff is wrapped correctly.

(2) If the user clothing restricts the normal blood flow, please 

     remove the clothing and repeat the measurement.

(3) Place the cuff over your left upper arm with your left palm 

     facing upward and ensure the cuff is at the same height with 

     your heart. Repeat the measurement.

Cuff inflation rate is too low or 

does not be inflated.

Measurement value is 

different from the hospital or 

the value is inconsistent.

Cuff deflates too quickly.

Measured value is abnormally 

high or low.

Содержание ESM201

Страница 1: ...is the standard Shenzhen Med link Electronics Tech Co Ltd ShanghaiInternationalHoldingCorp GmbH Europe Eiffestrasse 80 20537 Hamburg Germany Tel 49 40 2513175 Fax 49 40 255726 R E V A 0 4th and 5th Fl...

Страница 2: ......

Страница 3: ...e for neonatal infant and the people who can t express his her thought This device is used to non invasive measure human body s blood pressure Do not use it for other purpose Do not use this device cl...

Страница 4: ...CD full display Cuff connector Cuff Air hose 2 ON OFF button MEMORY button SET button USER button DOWN button UART port LCD display Cuff socket Battery compartment cover 3 1 Install or Replace Batteri...

Страница 5: ...Measurement To ensure the measurement accuracy please follows the below suggestions Do not eat drink smoke or exercise before measurement Take the measurement after urination and defecation Sit down...

Страница 6: ...er measurement is finished the cuff will deflation automatically then the systolic diastolic blood pressure pulse rate and blood pressure unit will be displayed and stored If the voice guided function...

Страница 7: ...r and get into the food chain damaging your health and well being 7 Maintenance and Storage 9 The below table explains the error code that may display on the LCD The below table explains the error cod...

Страница 8: ...IEC EN 60601 1 EMC IEC EN 60601 1 2 performance EN1060 1 3 IEC EN 80601 2 30 User manual Warranty card Gift box 80 105kPa 2x90 sets Temperature 20 C 55 C Humidity 95 RH non condensing The following s...

Страница 9: ...blishments including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Emissions test Compliance El...

Страница 10: ...ield strength in the location in which the model ESM201 is used exceeds the applicable RF compliance level above the model ESM201 should be observed to verify normal operation If abnormal performance...

Страница 11: ...ure exerted by circulating blood upon the walls of blood vessels and is one of the principal vital signs Two pressures are measured for a blood pressure reading Systolic blood pressure is a measure of...

Страница 12: ......

Отзывы: